This study focused on the mechanical behavior of reinforced lightweight aggregate concrete (RLAC) walls under repeated horizontal loads after a standard temperature-rising fire-resistance test and compared the specimen walls' ultimate loads, yielding loads, cracked loads, stiffness, and ductility with those of reinforced normal-weight aggregate concrete (RNAC) walls. Steel reinforcing bar spacing, aggregate types, wall widths, and high temperatures were variables in this study. The experimental results showed that, after the fire-resistance test, the smaller the steel reinforcing bar spacing of RLAC walls, the higher the yield and ultimate loads, yet the worse the ductility and the hysteresis loop's energy, whereas the greater the width of the wall, the greater the stiffness and the higher the hysteresis loop's energy. The differences in terms of stiffness, ductility, and hysteresis between RLAC walls with and without the fire-resistance test were insignificant, indicating that RLAC walls do not lose their basic mechanical behavior during a high-temperature fire. RNAC walls showed, indeed, a significant downward trend for strength and hysteresis after the fire-resistance test, but the decrease was much less clear for stiffness. Therefore, RLAC walls did show better seismic resistance than RNAC walls under the same testing conditions.
机译:这项研究的重点是经过标准的耐温耐火试验后,反复水平荷载下钢筋轻质骨料混凝土(RLAC)墙的力学性能,并将标本墙的极限荷载,屈服荷载,开裂荷载,刚度和延性与钢筋普通重量集料混凝土(RNAC)墙。钢筋间距,骨料类型,壁宽和高温是这项研究的变量。实验结果表明,耐火试验后,RLAC壁的钢筋间距越小,屈服强度和极限载荷越高,延展性和滞后回线的能量越差,而宽度越大。壁的刚度越大,磁滞回线的能量就越高。在进行和不进行耐火测试的情况下,RLAC墙之间的刚度,延展性和滞后性差异均不明显,这表明RLAC墙在高温火灾中不会失去其基本机械性能。实际上,RNAC壁在耐火性测试后显示出强度和滞后性的显着下降趋势,但对于刚度而言,下降幅度并不明显。因此,在相同的测试条件下,RLAC墙确实比RNAC墙具有更好的抗震性能。

著录项

  • 来源
    《Fire and materials》 |2014年第8期|789-805|共17页
  • 作者单位

    Department of Fire Science, Wu Feng University, 117 Jianguo Rd., Sec. 2, Minsyong, Chiayi, 62153, Taiwan;

    Department of Civil Engineering, National Chung Hsing University, 250 Kuo Kuang Road, Taichung, 40227, Taiwan;

    Department of Civil Engineering, National Chung Hsing University, 250 Kuo Kuang Road, Taichung, 40227, Taiwan;

    Department of Civil Engineering, National Chung Hsing University, 250 Kuo Kuang Road, Taichung, 40227, Taiwan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    reinforced lightweight aggregate concrete wall; fire-resistance test; mechanic behavior; hysteresis loop's energy; seismic resistance;

    机译:增强轻质骨料混凝土墙;耐火测试;机械行为磁滞回线的能量;抗震性;
  • 入库时间 2022-08-18 00:11:14

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号