Experimental study on the time-dependent smoke densities at 39 locations in a multi-floor building through a digital smoke detector system

机译:通过数字烟雾探测器系统对多层建筑中39个位置的时变烟气密度进行实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

The objective of this study was to quantitatively investigate some characteristics of the smoke transportation in multi-floor buildings. Eight experiments were conducted for worst scenario. The effects of an open window in the burning room on the smoke transportation are also analyzed. The time-dependent smoke densities at 39 locations in a half-scale building with an atrium were measured through a digital smoke detector system. The results indicate that the chimney effect plays an important role in the smoke transportation in multi-floor buildings with atriums. For the effects of the open window, the results suggest that the smoke densities at most locations in the building increase earlier when a window is open but have a smaller peak value than those results in the cases without any outer vents. It is suggested that a building without vertical atrium would be safer than those with long ones. More attention should be paid to those spaces when the fire protection systems are designed for buildings with atriums. The data of the time-dependent smoke densities at tens of locations in the building are useful for the validation of smoke transportation models.
机译:这项研究的目的是定量研究多层建筑中烟雾传输的一些特征。在最坏的情况下进行了八个实验。还分析了燃烧室中打开的窗户对烟雾传输的影响。通过数字烟雾探测器系统测量了带有中庭的半规模建筑物中39个位置随时间变化的烟雾密度。结果表明,烟囱效应在带有中庭的多层建筑的烟气运输中起着重要作用。对于开着的窗户的影响,结果表明,当窗户打开时,建筑物中大多数位置的烟气密度增加得较早,但峰值小于没有任何外部通风口的情况下的烟气密度。建议没有垂直中庭的建筑物比具有长中庭的建筑物更安全。当消防系统设计用于中庭建筑时,应更加注意这些空间。建筑物中数十个位置的随时间变化的烟雾密度数据可用于验证烟雾传输模型。

著录项

  • 来源
    《Fire and materials》 |2014年第5期|507-528|共22页
  • 作者单位

    State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, 230027, China;

    Honeywell Technology Solution-China, 430 Li Bing Road, Shanghai, 201203, China;

    Honeywell Life Safety, 3825 Ohio Avenue, St. Charles, IL 60174, USA;

    Honeywell Life Safety, 3825 Ohio Avenue, St. Charles, IL 60174, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    smoke transportation; time-dependent smoke density; chimney effect;

    机译:烟雾运输;随时间变化的烟雾密度;烟囱效应;