Column-tree moment resisting frames, as the efficient shop-welded and field-bolted structural systems, are used in many countries. Very limited research has been carried out on such systems under fire conditions. This paper presents experimental and numerical investigations of the behavior of beam and bolted splice connections in steel column-tree moment resisting frames exposed to fire. Two full-scale steel sub-frames with different splice connections were tested under International Organization for Standardization (ISO 834) fire. The observation of thermal and structural fire behaviors including temperature histories, temperature deflection of the beam, temperature rotation of splice connections, and failure modes was investigated. The beam splice connection failed because of shear fracture of top bolts at temperatures beyond 750 degrees C, while beam underwent large deflections of more than span/20. In addition, detailed 3-D finite element models were developed to simulate the structural behavior of the specimens in fire. Obtained numerical results from the finite element analysis successfully simulated the experimental fire test results. Copyright (c) 2015 John Wiley & Sons, Ltd.
机译:在许多国家/地区中,作为有效的车间焊接和现场锚固结构系统,柱-树抗弯框架得到了应用。在火灾情况下,对此类系统的研究非常有限。本文介绍了在火灾中承受钢柱-树的抗弯框架中梁和螺栓连接的性能的实验和数值研究。在国际标准化组织(ISO 834)防火下测试了两个具有不同接头连接的全尺寸钢子框架。观察了热和结构火灾行为,包括温度历史记录,梁的温度挠度,接头连接的温度旋转以及破坏模式。由于在750摄氏度以上的温度下顶部螺栓的剪切断裂,导致梁的拼接连接失败,而梁承受的大挠度超过span / 20。此外,还开发了详细的3-D有限元模型来模拟火中标本的结构行为。从有限元分析中获得的数值结果成功地模拟了实验性火试验结果。版权所有(c)2015 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号