In this work, cone calorimeter tests were conducted to investigate fire properties of interior materials (floor covering [FC], aluminum plate covered with paint [APCP], light diffuser [LD], and gel coat [GC]) used in low-floor light-rail trains. Ignition time (t(ig)) of each material decreases with the increase of radiative heat flux. The decreasing order of the four samples by ignition time under the same radiative heat flux is LD > APCP > FC > GC. The heat release rate (HRR), peak value of HRR (PHRR), time from ignition to PHRR (t(p)), fire growth rate index (FIGRA), and fire growth index (FGI) rise with the increasing radiative heat flux. For the FC, LD, and GC, single HRR peak is observed in the HRR history while three peaks are observed for APCP. For PHRR, LD > FC > APCP > GC, while for t(p), GC < FC < APCP < LD. Under most conditions, the FIGRA and FGI of the FC is the highest among the four materials. Results of this work are beneficial to evaluate fire hazard of low-floor light-rail train and determine the emphasis of fire prevention.
机译:在这项工作中,进行了锥形量热仪测试,以调查用于低地板的内部材料(地板覆盖层[FC],铝板涂有油漆[APCP],光扩散板[LD]和胶衣[GC])的防火性能轻轨列车。每种材料的点火时间(t(ig))随辐射热通量的增加而减少。在相同的辐射热通量下,四个样品随点火时间的递减顺序为LD> APCP> FC> GC。放热率(HRR),HRR峰值(PHRR),从点火到PHRR的时间(t(p)),火速生长指数(FIGRA)和火速生长指数(FGI)随着辐射热通量的增加而增加。对于FC,LD和GC,在HRR历史记录中观察到单个HRR峰,而对于APCP观察到三个峰。对于PHRR,LD> FC> APCP> GC,而对于t(p),GC

著录项

  • 来源
    《Fire and materials》 |2019年第8期|1003-1009|共7页
  • 作者单位

    China Univ Min & Technol Jiangsu Key Lab Fire Safety Urban Underground Spa Xuzhou 221116 Jiangsu Peoples R China|China Univ Min & Technol Key Lab Gas & Fire Control Coal Mines Minist Educ Xuzhou Jiangsu Peoples R China|Key Lab Bldg Fire Protect Engn & Technol MEM Tianjin Peoples R China;

    China Univ Min & Technol Jiangsu Key Lab Fire Safety Urban Underground Spa Xuzhou 221116 Jiangsu Peoples R China|China Univ Min & Technol Key Lab Gas & Fire Control Coal Mines Minist Educ Xuzhou Jiangsu Peoples R China;

    Jiangsu Univ Technol Sch Automot & Traff Engn Changzhou Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    cone calorimeter test; heat release rate; ignition time; interior material fire properties; low-floor light-rail train;

    机译:锥形量热仪测试放热率点火时间内部材料的防火性能;低层轻轨火车;