The tests confirmed and demonstrated the following: 1. Airflow volumes introduced into the fire area by solid-bore and straight streams from combination nozzles are very similar. 2. Air moved by solid-bore nozzles and straight streams from combination nozzles do not disturb the fire environment and did not create untenable conditions for firefighters under the three ventilation conditions tested here. 3. Fog nozzles move so much air volume into the fire area that even a large ventilation opening cannot relieve the overpressure created, thus resulting in a ricochet of air from the fire area back to the attack team. Much has been written regarding the use of fog and solid-bore nozzles. The tests described here for the first time provide firefighters with an easy, repeatable, and safe method for comparing the effects of solid and fog streams on an interior fire attack.
机译:测试证实并证明以下几点:1.由组合喷嘴的实心孔和直流引入火区的气流量非常相似。 2.在此处测试的三种通风条件下,由实心喷嘴移动的空气和来自组合喷嘴的直流不会干扰消防环境,并且不会为消防员造成不便的条件。 3.雾状喷嘴将大量的空气移动到着火区域,以至于即使大的通风口也无法缓解所产生的过压,从而导致空气从着火区域流回攻击团队。关于雾气喷嘴和实心喷嘴的使用,已经有很多著作。此处首次描述的测试为消防员提供了一种简单,可重复且安全的方法,用于比较固体和雾流对内部火势的影响。