Scissor stairs are a spacesaving device. Two stairways are located in one shaft. Consider stairway A: Its doorway on the fifth floor is in a certain location; its doorways on the fourth and sixth floors will be in different locations and perhaps be blocked off by a partition . The doorways for stairway B on the floors above and below will be directly above the doorway for stairway A. When operating at a fire in a multistory building, Command might decide that stairway A is to be the attack stairway and stairway B the exit stairway. This is an attempt to keep the exit stairway clear of firefighters, hoselines, and smoke. In a New York City fire, firefighters discovered that all the stairway doors in one vertical line were designated "A" and in the other "B." This could cause a deadly delay.
机译:剪式楼梯是一种节省空间的装置。两个楼梯位于一个竖井中。考虑楼梯A:它在五楼的门口在某个位置。它在四楼和六楼的门口会在不同的位置,也许被一个隔板挡住。上下两层的楼梯B的门道将位于楼梯A的门道的正上方。在多层建筑物中着火时,司令部可能会确定楼梯A为进攻楼梯,楼梯B为出口楼梯。这是为了使出口楼梯远离消防员,软管和烟雾。在纽约市的一场大火中,消防员发现一条垂直线中的所有楼梯门均标为“ A”,另一条垂直线标为“ B”。这可能会导致致命的延迟。