摘要

The self-storage facilities considered below are generally one- or two-story buildings featuring prefabricated lightweight metal or concrete-block construction. Although they share similar problems and hazards with all self-storage facilities, these construction types seem to suffer the most at fire incidents. The incident commander's (IC's) major concerns operating at a fire at a self-storage building are the lightweight construction's collapse potential; the enormous amount of sometimes densely packed, combustible contents; and the unknown hazardous materials or liquids stored within.
机译:以下考虑的自助存储设施通常是一层或两层的建筑物,具有预制的轻质金属或混凝土砌块结构。尽管它们与所有自存储设施都存在类似的问题和危害,但这些建筑类型似乎在发生火灾时受害最大。事故指挥官(IC)在自存储建筑物着火的情况下主要关注的问题是轻型建筑物的倒塌可能性。大量有时密集包装的可燃物品;以及其中存储的未知危险物质或液体。