ON JANUARY 18, 2017, AT 7:53 A.M., Fort Lauderdale (FL) Fire Department (FLFD) units responded to a large warehouse fire with unknown chemicals involved in the "Uptown Business District" of the city. On arrival, initial responding units were met with a well-involved 300- x 100-foot, 30,000-square-foot warehouse with heavy fire showing through the roof. The one-story building was of type II (noncombusti-ble) construction, consisting of concrete block walls and a metal deck roof supported by lightweight, unprotected steel bar joists (parallel chord trusses). The fire building was H-shaped; a courtyard and loading docks were on three sides of the structure. Visability and access to the structure were limited, as the structure bordered a canal in an industrial park in an unincorporated part of the city that had few hydrants and access roads.
机译:2017年1月18日凌晨7:53,劳德代尔堡(FL)消防部门(FLFD)响应了涉及该城市“上城区商业区”的大型仓库火灾,其中化学品未知。到达后,最初的反应部队遇到了一个涉及范围广的300 x 100英尺,30,000平方英尺的仓库,屋顶有大火。这座单层建筑为II型(不燃)建筑,由混凝土砌块墙和金属甲板屋顶组成,并由轻型无保护的钢筋托梁(平行弦桁架)支撑。消防大楼是H形的。院子和装卸码头位于结构的三个侧面。可见性和进入该结构的机会受到限制,因为该结构与城市中未经注册的部分的工业园区中的一条运河接壤,该城市几乎没有消防栓和通路。