Occupant acceptance as a screening parameter for indoor environmental assessments

机译:乘员接受作为室内环境评估的筛选参数

获取原文
获取原文并翻译 | 示例

摘要

Purpose - This study seeks to investigate the usefulness of occupant acceptance as a preliminaryrnscreen measure for offices' indoor air quality (IAQ). An effective alert indication of IAQ problems of arnconcerned indoor environment would help to promote good IAQ.rnDesign/methodology/approach - The study evaluates the hypothesis that the occupantrndissatisfaction with the overall indoor environment provides an indication of IAQ problems. Hence,rnoccupant dissatisfaction would be used as a screening parameter to identify problematic IAQrnregarding some IAQ criteria in subsequent IAQ assessments. The hypothesis was tested with arndatabase of regional cross-sectional measurement in 490 offices within Hong Kong.rnFindings - The occupants' dissatisfaction with the indoor environmental quality (IEQ) wasrncorrelated with the IAQ assessment results of nine IAQ assessment parameters regarding some IAQrncriteria for air-conditioned offices. At certain screening levels of predicted IEQ dissatisfaction, thernperformance of the proposed screening tool, indicating unsatisfactory office IAQ, was evaluated inrnterms of the test sensitivity, specificity, predictive values and Yule's Q statistics. The results showedrnthat occupants' response to the indoor environment produced indications of unsatisfactory IAQrnregarding the requirement of an "Excellent" office.rnResearch limitations/implications - The subjective feelings of occupants are capable ofrnidentifying marked indoor environmental problems, but cannot identify the "marginal" IAQ problemrncases.rnPractical implications - The study shows the usefulness of using occupant acceptance to identifyrnthe unrecognized IAQ problems for air-conditioned office environment. Using the identification modelrndeveloped in the study, all the suspected cases were associated with a high chance of IAQrndissatisfaction and subsequent IAQ assessments were thus recommended.rnOriginality/value - The paper proposes a new identification method to identify the unrecognizedrnIAQ problems which may indicate unsatisfactory IAQ. Also, the occupants' responses on the indoorrnenvironment are quantified.
机译:目的-本研究旨在调查占用者接受作为办公室室内空气质量(IAQ)的初步筛查措施的有用性。一个有效的关于室内环境的IAQ问题的预警指示将有助于促进良好的IAQ。设计/方法/方法-该研究评估了一个假设,即居住者对整个室内环境的不满会提供IAQ问题的指示。因此,在随后的IAQ评估中,对居住者的不满将用作筛选参数,以识别出一些IAQ标准存在问题的IAQ。该假设已在香港490个办事处的区域横截面测量的arndb数据库中进行了检验。有条件的办公室。在预测的IEQ不满意的某些筛选水平下,对拟议的筛选工具的性能(表示办公室IAQ不满意)进行了评估,包括测试灵敏度,特异性,预测值和Yule's Q统计数据。结果表明,对于“优良”办公室的要求,居住者对室内环境的反应导致室内空气质量不能令人满意。研究限制/含义-居住者的主观感觉能够识别明显的室内环境问题,但无法识别“边际”室内空气质量问题-实际意义-该研究表明,在空调办公室环境中,使用乘员接受来识别无法识别的IAQ问题很有用。使用研究中开发的识别模型,所有可疑病例都可能引起IAQ不满意,因此建议进行随后的IAQ评估。rnriginity / value-本文提出了一种新的识别方法,以识别可能无法表明IAQ的IAQ问题。而且,量化了乘客对室内环境的反应。

著录项

  • 来源
    《Facilities 》 |2010年第8期| P.338-347| 共10页
  • 作者

    P.S. Hui; L.T. Wong; K.W. Mui;

  • 作者单位

    Department of Building Services Engineering,The Hong Kong Polytechnic University, Hong Kong, China;

    Department of Building Services Engineering,The Hong Kong Polytechnic University, Hong Kong, China;

    Department of Building Services Engineering,The Hong Kong Polytechnic University, Hong Kong, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    environmental testing; office buildings; Hong Kong;

    机译:环境测试;办公大楼;香港;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号