This paper reports the results of measurements performed on five standard weights of class F2, by several metrology laboratories throughout Romania. The comparison began in 2009 and concluded in 2010. Mass Laboratory of National Institute of Metrology (INM) acted as pilot laboratory (PL) and reference laboratory (RL) for the programme. Five standard weights of class F2 (nominal values: 5 kg, 1 kg, 200 g, 100 g and 10 g) were sent to the participants. The laboratory’s results are presented for each weight, along with the associated uncertainty and the normalized errors of each laboratory, with respect to the INM. The results obtained by the participating laboratories in this comparison can be used to validate the measurement capabilities (in the calibration of weights) claimed/approved under the quality management systems.
机译:本文报告了罗马尼亚的多个计量实验室对F2类的五个标准砝码进行的测量结果。比较从2009年开始,到2010年结束。国家计量学院的质量实验室(INM)担任该计划的试验实验室(PL)和参考实验室(RL)。将五种标准重量的F2类(标称值:5 kg,1 kg,200 g,100 g和10 g)发送给参与者。列出了每个重量的实验室结果,以及每个实验室相对于INM的相关不确定性和归一化误差。参与实验室在此比较中获得的结果可用于验证在质量管理体系下要求/批准的测量能力(在重量校准中)。