Lead (Pb) poisoning is a significant threat faced by raptors. Hence, rapid Pb diagnosis has become a priority during the admission of raptors in wildlife recovery centers, and bench-top analyzers, such as LeadCare II (R), are routinely employed for this purpose. However, this device has been designed for conducting analyses of human blood Pb levels (BLLs), and the validity of this methodology for whole blood from raptors has, to date, rarely been assessed. In addition, a recent recall by the US Food and Drug Administration has recommended discontinuing the use of this analyzer for human venous blood because it may underestimate the BLL. We evaluated the precision of BLL measurements taken with LeadCare II by comparing them with those obtained with inductively coupled plasma mass spectrometry (ICP-MS). Our sample contained venous blood from 105 raptors belonging to 4 species. The results showed a good correlation between the 2 techniques (Spearman's r = 0.927, p 0.0001). The mean BLL with ICP-MS was 19.6 mu g/dL; it was found to be 18.7 mu g/dL with LeadCare II. A Bland-Altman analysis indicated that the bias between the mean differences was only 0.5 mu g/dL, but it had a high standard deviation of bias (5.7 mu g/dL) and 95% limits of agreement from -10.75 to 11.74 mu g/dL. The present results indicated that LeadCare II has an overall sensitivity of 71.8% and a positive predictive value of 76.3%. The specificity of LeadCare II for detecting animals with low BLL (3.4 mu g/dL) was 96.4%, and the negative predictive value (the probability that a value below the limit of detection of LeadCare II has a true correspondence with the actual value) was 100%. The present results indicated that, although LeadCare II might be imperfect in the estimation of BLLs in raptors, it performs reasonably well and might be employed in the clinical setting to assess patients potentially suffering from Pb poisoning. Environ Toxicol Chem 2019;38:737-747. (c) 2018 SETAC
机译:铅(PB)中毒是猛龙队面临的重大威胁。因此,快速的PB诊断在野生动物恢复中心的猛龙队的敲诈纳森中成为优先权,而是为了此目的,常规使用绳索的分析仪,例如Leadcare II(R)。然而,该装置专为进行人血PB水平(BLL)的分析而设计,并且迄今为止,从猛龙队的全血的这种方法的有效性很少被评估。此外,美国食品和药物管理局最近召回推荐停止使用这种分析仪的人类静脉血液,因为它可能低估了BLL。通过将引线II与用电感耦合等离子体质谱(ICP-MS)获得的那些,我们评估了用Leadcare II进行的BL1测量的精度。我们的样品包含来自属于4种的105张猛禽的静脉血。结果表明,2技术之间存在良好的相关性(Spearman的R = 0.927,P <0.0001)。具有ICP-MS的平均值为19.6μg/ dL;它被发现是18.7μg/ dl,具有铅II。一个平坦的altman分析表明,平均差异之间的偏差仅为0.5μg/ dl,但它具有高标准偏差(5.7 mu g / dl)和95%的协议限制--10.75至11.74 mu g / dl。本结果表明,铅II的总敏感性为71.8%,阳性预测值为76.3%。用于检测具有低BL1(<3.4μg/ dl)的动物的引用II的特异性为96.4%,负预测值(低于Leadcare II的检测限的值与实际值的真实对应的概率)是100%。目前的结果表明,虽然Leadcare II可能是不完美的,但在猛龙队中的BLL估计中可能是合理的,并且可能在临床环境中使用,以评估患有PB中毒的患者。环境毒素化学2019; 38:737-747。 (c)2018 Setac

著录项

  • 来源
    《Environmental toxicology and chemistry》 |2019年第4期|737-747|共11页
  • 作者单位

    Grp Rehabil Fauna Autoctona & Habitat GREFA Madrid Spain|Study Grp Wild Anim Conservat Med GEMAS Madrid Spain;

    Study Grp Wild Anim Conservat Med GEMAS Madrid Spain;

    Grp Rehabil Fauna Autoctona & Habitat GREFA Madrid Spain|Study Grp Wild Anim Conservat Med GEMAS Madrid Spain;

    Univ Las Palmas Gran Canaria Res Inst Biomed & Hlth Sci IUIBS Toxicol Unit Las Palmas Gran Canaria Spain;

    Study Grp Wild Anim Conservat Med GEMAS Madrid Spain|Univ Complutense Madrid Vet Fac Madrid Spain;

    Study Grp Wild Anim Conservat Med GEMAS Madrid Spain|Univ Las Palmas Gran Canaria Res Inst Biomed & Hlth Sci IUIBS Toxicol Unit Las Palmas Gran Canaria Spain|Spanish Biomed Res Ctr Physiopathol Obes & Nutr C Madrid Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Lead; Raptors; Vultures; Inductively coupled plasma-mass spectrometry; Clinical laboratory analysis; Heavy metals;

    机译:铅;猛龙;秃鹰;电感耦合等离子体质谱;临床实验室分析;重金属;