There is an urgent need to develop regulatory guidelines for compounds classed as "difficult substances"—poorly water-soluble, volatile, readily biodegradable or photodegradable, or hydrolytically unstable compounds. The project METIER (modular ecotoxicity tests incorporating ecological relevance) aims to develop a series of ecologically relevant toxicity tests allowing the full breadth of response of aquatic organisms to chemical contaminants to be assessed under realistic exposure scenarios. This involves the development of a standard flow-through exposure system and a series of modular toxicity tests linked to a mechanistic physiological model of contaminant effects. This paper addresses the initial stages of the development and test design of the module with Aedes aegypti larvae (Diptera: Culicidae), using 3,4-dichloroaniline (3,4-DCA), a poorly water-soluble compound included in the European Community Priority 1 List of Chemicals. A viable culture system, suitable test medium, and the experimental design for loading effects and test duration are investigated. Moreover, the dissolution process and stability of the 3,4-DCA solutions are presented. Up to 50 mg L~(-1) 3,4-DCA was dissolved without the use of a carrier. There was no loss of chemical during 4 d after dissolution. Use of one larva per vessel in 96-h acute toxicity tests is recommended. Also, 24-, 48-, 72-, and 96-h acute toxicity tests were run in low and high volumes of medium. Results of these tests reveal that A. aegypti larvae are more sensitive in higher volumes of test medium and belong to a moderately tolerant group of organisms regarding 3,4-DCA acute toxicity.
机译:迫切需要为归类为“难溶物质”的化合物制定监管准则,这些化合物难溶于水,易挥发,易于生物降解或光降解或水解不稳定。 METIER项目(包含生态相关性的模块化生态毒性测试)旨在开发一系列与生态相关的毒性测试,允许在现实的暴露场景下评估水生生物对化学污染物的完整反应。这涉及标准流通式接触系统的开发以及与污染物影响机理生理学模型相关的一系列模块化毒性测试。本文介绍了埃及伊蚊幼虫(双翅目:Culicidae)使用3,4-二氯苯胺(3,4-DCA)(一种难溶于水的化合物,在欧洲共同体中)开发和测试设计的初始阶段。优先级1化学品清单。研究了可行的培养系统,合适的测试培养基以及负载效应和测试持续时间的实验设计。此外,介绍了3,4-DCA溶液的溶解过程和稳定性。在不使用载体的情况下最多溶解了50 mg L〜(-1)3,4-DCA。溶解后4 d内无化学损失。建议在96小时的急性毒性试验中,每个容器使用一个幼虫。此外,在低和大量培养基中进行了24、48、72和96小时的急性毒性试验。这些测试的结果表明,埃及伊蚊的幼虫在较大体积的测试培养基中更为敏感,并且属于对3,4-DCA急性毒性具有中等耐受性的生物体。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号