Two laboratory performance studies with 21 and 11 participants were carried out for passive sampling of nonpolar chemicals in water, using silicone samplers that were deployed for 7 wk and 13 wk at 2 river sites in the Netherlands. Target analytes were polychlorinated biphenyls, polycyclic aromatic hydrocarbons (PAHs), polybrominated diphenyl ethers (PBDEs), hexachlorobutadiene, hexachlorobenzene, and a number of performance reference compounds (PRCs). Calculation of aqueous concentrations based on prescribed input values and a prescribed uptake model was also included. Between-laboratory coefficients of variation (CVs) in the analysis of target compounds were approximately 20% at concentrations of 100 ng g(-1) and approximately 100% at concentrations of 0.01 ng g(-1), which was similar to previous results for the analysis of biota samples. The analysis of PRCs yielded water sampling rates with a between-laboratory CV of 18% to 30%. The sampling rate model showed a nearly perfect match with the consensus values of retained PRCs. The implications of the present study for future interlaboratory exercises are discussed. (C) 2016 SETAC
机译:进行了两项针对21名和11名参与者的实验室性能研究,目的是使用有机硅采样器对水中的非极性化学物质进行被动采样,该采样器分别在荷兰的2个河流站点部署了7周和13周。目标分析物是多氯联苯,多环芳烃(PAH),多溴联苯醚(PBDE),六氯丁二烯,六氯苯和许多性能参考化合物(PRC)。还包括根据规定的输入值和规定的吸收模型计算水浓度。目标化合物分析中的实验室间变异系数(CV)在100 ng g(-1)的浓度下约为20%,在0.01 ng g(-1)的浓度下约为100%用于分析菌群样品。对PRC的分析得出实验室间CV为18%至30%的水采样率。抽样率模型显示与保留的中华人民共和国的共识值几乎完美匹配。讨论了本研究对未来实验室间练习的意义。 (C)2016年SETAC

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号