EFFLUENT QUALITY OF A CONVENTIONAL ACTIVATED SLUDGE AND A MEMBRANE BIOREACTOR SYSTEM TREATING HOSPITAL WASTEWATER

机译:常规活性污泥和膜生物反应器系统处理医院废水的有效质量

获取原文
获取原文并翻译 | 示例
       

摘要

Two lab scale wastewater treatment plants treating hospital wastewater in parallel were compared in terms of performance characteristics. One plant consisted of a conventional activated sludge system (CAS) and comprised an anoxic and aerobic compartment followed by a settling tank with recycle loop. The second pilot plant was a plate membrane bioreactor (MBR). The wastewater as obtained from the hospital had a variable COD (Chemical Oxygen Demand) ranging from 250 to 2300 mg l~(-1). Both systems were operated at a similar hydraulic residence time of 12 hours. The reference conventional activated sludge system did not meet the regulatory standard for effluent COD of 125 mg l~(-1) most of the time. Its COD removal efficiency was 88%. The plate MBR delivered an effluent with a COD value of 50 m g l~(-1) or less, and attained an efficiency of 93%. The effluent contained no suspended particles. In addition, the MBR resulted in consistent operational parameters with a flux remaining around 8 - 10 l m~(-2) h~(-1) and a trans membrane pressure < 0.1 bar without the need for backwash or chemical cleaning. The CAS and the MBR system performed equally well in terms of TAN removal and EE2 removal. The CAS system typically decreased bacterial groups for about 1 log unit, whereas the MBR decreased these groups for about 3 log units. Enterococci were decreased below the detection limit in the MBR and indicator organisms such as fecal coliforms were decreased for 1.4 log units in the CAS system compared to a 3.6 log removal in the MBR.
机译:比较了两个实验室规模的污水处理厂并行处理医院污水的性能特征。一间工厂由传统的活性污泥系统(CAS)组成,包括一个缺氧和好氧的隔室,然后是一个带有循环回路的沉淀池。第二个中试工厂是板膜生物反应器(MBR)。从医院获得的废水的COD(化学需氧量)变化范围为250至2300 mg l〜(-1)。两种系统均以类似的12小时液压停留时间运行。常规参考活性污泥系统大多数时候不符合废水COD的管理标准,为125 mg l〜(-1)。其COD去除效率为88%。平板MBR排出的COD值为50 m g l〜(-1)或更小,效率达到93%。流出物不含悬浮颗粒。另外,MBR产生了一致的运行参数,通量保持在8-10 l m〜(-2)h〜(-1)左右,跨膜压力<0.1 bar,无需反冲洗或化学清洗。在TAN去除和EE2去除方面,CAS和MBR系统均表现出色。 CAS系统通常减少细菌群约1个对数单位,而MBR减少这些细菌群约3个对数单位。肠球菌在MBR中降至检测限以下,而粪便大肠菌等指示生物在CAS系统中降低了1.4 log单位,而MBR中则去除了3.6 log。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号