A bench-scale continuous flow dissolved air flotation (DAF) system was operated using Winnipeg tap water. Three different dosages of alum were applied: 41.7 mg 1~(-1), 25.5 mg 1~(-1) and 15.5 mg 1~(-1). Floc size distributions formed at different coagulant dosages were analyzed to identify characteristics of floc size distribution optimal for flotation. Alum dose of 25.5 mg 1~(-1) was found to be optimal for the bench scale DAF unit in this study. At this dosage, the DAF effluent achieved a turbidity of 0.25 NTU and color of 3.8 TCU, significantly lower than that for the tap water. The optimum floc size distribution at the dose of 25 mg 1~(-1) had the logarithmic mean size of 27 μm which was close to the size of air bubbles produced by the saturator in this study (30 μm). The results of this study suggest that the DAF treatment process is optimized when the logarithmic mean floe size and bubble size are equal.
机译:使用温尼伯自来水运行台式规模的连续流溶气浮选(DAF)系统。施用三种不同剂量的明矾:41.7 mg 1〜(-1),25.5 mg 1〜(-1)和15.5 mg 1〜(-1)。分析在不同凝结剂剂量下形成的絮凝物尺寸分布,以鉴定最适于浮选的絮凝物尺寸分布的特征。在这项研究中,发现明矾剂量为25.5 mg 1〜(-1)对于台式DAF装置是最佳的。在此剂量下,DAF废水的浊度为0.25 NTU,颜色为3.8 TCU,显着低于自来水的浊度。剂量为25 mg 1〜(-1)时,最佳絮团尺寸分布的对数平均尺寸为27μm,接近于本研究中饱和器产生的气泡尺寸(30μm)。这项研究的结果表明,当对数平均絮凝物大小和气泡大小相等时,DAF处理工艺将得到优化。