首页> 外文期刊>Environmental Technology >A plant-wide energy model for wastewater treatment plants: application to anaerobic membrane bioreactor technology
【24h】

A plant-wide energy model for wastewater treatment plants: application to anaerobic membrane bioreactor technology

机译:废水处理厂的全厂能源模型:在厌氧膜生物反应器技术中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study is to propose a detailed and comprehensive plant-wide model for assessing the energy demand of different wastewater treatment systems (beyond the traditional activated sludge) in both steady- and unsteady-state conditions. The proposed model makes it possible to calculate power and heat requirements (W and Q, respectively), and to recover both power and heat from methane and hydrogen capture. In order to account for the effect of biological processes on heat requirements, the model has been coupled to the extended version of the BNRM2 plant-wide mathematical model, which is implemented in DESSAS simulation software. Two case studies have been evaluated to assess the model's performance: (1) modelling the energy demand of two urban wastewater treatment plants based on conventional activated sludge and submerged anaerobic membrane bioreactor (AnMBR) technologies in steady-state conditions and (2) modelling the dynamics of reactor temperature and heat requirements in an AnMBR plant in unsteady-state conditions. The results indicate that the proposed model can be used to assess the energy performance of different wastewater treatment processes and would thus be useful, for example, WWTP design or upgrading or the development of new control strategies for energy savings.
机译:这项研究的目的是提出一个详细而全面的全厂模型,以评估稳态和非稳态条件下不同废水处理系统(除了传统的活性污泥)的能源需求。提出的模型可以计算功率和热量需求(分别为W和Q),并可以从甲烷和氢气捕获中回收功率和热量。为了考虑生物过程对热量需求的影响,该模型已与BNRM2全厂范围数学模型的扩展版本耦合,该模型在DESSAS仿真软件中实现。已评估了两个案例研究以评估该模型的性能:(1)在稳态条件下基于常规活性污泥和浸没式厌氧膜生物反应器(AnMBR)技术对两个城市废水处理厂的能源需求进行建模,以及(2)对模型进行建模。非稳态条件下AnMBR工厂反应堆温度和热量需求的动态变化。结果表明,所提出的模型可用于评估不同废水处理过程的能源绩效,因此将非常有用,例如,污水处理厂的设计或升级或开发新的节能控制策略。

著录项

  • 来源
    《Environmental Technology》 |2016年第20期|2298-2315|共18页
  • 作者单位

    Univ Politecn Valencia, Inst Univ Invest Engn Aigua & Medi Ambient, IIAMA, Cami Vera S-N, E-46022 Valencia, Spain;

    Univ Politecn Valencia, Inst Univ Invest Engn Aigua & Medi Ambient, IIAMA, Cami Vera S-N, E-46022 Valencia, Spain;

    Univ Valencia, Escola Tecn Super Engn, Dept Engn Quim, Valencia, Spain;

    Univ Valencia, Escola Tecn Super Engn, Dept Engn Quim, Valencia, Spain;

    Univ Politecn Valencia, Inst Univ Invest Engn Aigua & Medi Ambient, IIAMA, Cami Vera S-N, E-46022 Valencia, Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Anaerobic MBR; BNRM2; DESASS; plant-wide energy model; wastewater treatment;