首页> 外文期刊>Environmental progress & sustainable energy >Experimental Investigation of an Air Heating System Using Different Types of Heat Exchangers Incorporated with an Evacuated Tube Solar Collector
【24h】

Experimental Investigation of an Air Heating System Using Different Types of Heat Exchangers Incorporated with an Evacuated Tube Solar Collector

机译:装有真空管太阳能集热器的不同类型热交换器的空气加热系统的实验研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this article, the thermal performance of a solar air heating system is experimentally investigated. In this system, an evacuated tube solar water heater is connected to a heat exchanger with connecting pipes. The evacuated tubes are used to produce hot water. This hot water flows to the heat exchanger through connecting pipes, the flow of hot water occurs due to thermosyphon phenomenon. Hot air is generated by passing ambient air through the heat exchanger. Three different types of heat exchanger viz. type-Ⅰ, type-Ⅱ and type-Ⅲ have been used. The height of the heat exchangers has been varied from 1050 mm to 1800 mm to evaluate the effect of height variation on the natural circulation flow rate of hot water. The maximum measured temperature difference between the hot air and the ambient air achieved was 10. TC which was obtained with the heat exchanger type-Ⅱ at the height of heat exchanger from ground level of 1550 mm.
机译:在本文中,对太阳能空气加热系统的热性能进行了实验研究。在该系统中,真空管太阳能热水器通过连接管连接到热交换器。真空管用于产生热水。该热水通过连接管流到热交换器,由于热虹吸现象而发生热水的流动。通过使环境空气流经热交换器来产生热空气。三种不同类型的热交换器。使用了Ⅰ型,Ⅱ型和Ⅲ型。换热器的高度已从1050 mm更改为1800 mm,以评估高度变化对热水自然循环流量的影响。测得的热空气和环境空气之间的最大温度差为10 TC。该温度是使用Ⅱ型热交换器在热交换器高度处离地面1550 mm处获得的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号