In this study, three different methods for determining the optimum thickness of used insulation material in external walls of building are presented. The first method is life cycle cost based on the energetic costs. The second method is thermoeconomic optimization based on the cost of insulation materials and fuel. Finally, the third method is optimization of insulation thickness by Turkish Thermal Insulation Standard-TS 825 based on heat energy requirement of buildings. The results show that the optimum insulation thicknesses vary between 3.2 and 12 cm, energy savings vary between 2.63 $/m~2 and 4.35 $/m~2, and payback periods vary between 1.7 and 2.7 yrs depending on the city and optimization method.
机译:在这项研究中,提出了三种不同的方法来确定建筑物外墙中使用的隔热材料的最佳厚度。第一种方法是基于能量成本的生命周期成本。第二种方法是根据隔热材料和燃料的成本进行热经济优化。最后,第三种方法是根据建筑物的热能需求,通过土耳其隔热标准TS 825优化隔热层厚度。结果表明,最佳绝缘厚度在3.2至12 cm之间变化,节能量在2.63 $ / m〜2与4.35 $ / m〜2之间变化,投资回收期在1.7至2.7年之间,具体取决于城市和优化方法。

著录项

  • 来源
    《Environmental progress》 |2011年第4期|p.709-719|共11页
  • 作者单位

    Department of Mechanical Engineering, Firat University, 23279 Elazig, Turkey;

    Department of Mechanical Engineering, Firat University, 23279 Elazig, Turkey;

    The Ministry of Public Works and Settlement, Elazig, Turkey;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    insulation thickness; optimization; thermoeconomic;

    机译:绝缘厚度优化;热经济学;
  • 入库时间 2022-08-17 13:29:06

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号