首页> 外文期刊>Environmental Pollution >Calibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water
【24h】

Calibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water

机译:被动采样水中持久性有机污染物的三油精嵌入式醋酸膜的校准和现场性能

获取原文
获取原文并翻译 | 示例
       

摘要

Triolein embedded cellulose acetate membrane (TECAM) passive samplers provide potentially powerful tool for monitoring time weighted average concentrations (C_(TWA)) of trace hydrophobic organic contaminants in water. To study the field performance of TECAM, exchange kinetics of chemicals between water and TECAM were studied at different temperature and water flow rates. Results showed that the uptake rate constant (k_u) in TECAM was less sensitive to temperature variation than the SPMD and Chemcatcher. The k_u in TECAM was sensitive to even a slight change of the flow rate, which required the field calibration using performance reference compounds (PRCs). To estimate C_(TWA) by TECAM, both empirical model and WBL model were compared in laboratory conditions, and only small differences were observed between the predicted and measured k_u. Field validation was conducted to test the sampler performance alongside spot sampling. A good agreement of water concentration was obtained by the two sampling techniques.
机译:甘油三油酸酯嵌入式醋酸纤维素膜(TECAM)被动采样器为监测水中痕量疏水性有机污染物的时间加权平均浓度(C_(TWA))提供了潜在的强大工具。为了研究TECAM的田间性能,研究了在不同温度和水流量下水与TECAM之间化学物质的交换动力学。结果表明,与SPMD和Chemcatcher相比,TECAM中的吸收速率常数(k_u)对温度变化不那么敏感。 TECAM中的k_u甚至对流量的微小变化都很敏感,这需要使用性能参考化合物(PRC)进行现场校准。为了通过TECAM估算C_(TWA),在实验室条件下比较了经验模型和WBL模型,并且在预测和测量k_u之间仅观察到很小的差异。进行现场验证以测试采样器性能和现场采样。通过两种采样技术获得了良好的水浓度一致性。

著录项

  • 来源
    《Environmental Pollution》 |2012年第5期|158-163|共6页
  • 作者单位

    State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China;

    State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China;

    State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China;

    State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China;

    State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China;

    State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Calibration; Triolein embedded cellulose acetate; membranes TECAM; Performance reference compounds PRCs; Passive sampling;

    机译:校准;三油精包埋的醋酸纤维素;膜TECAM;性能参考化合物PRC被动取样;