HYDRAULIC BALANCING ANALYSIS OF A CENTRAL HEATING SYSTEM WITH CONSTANT SUPPLY TEMPERATURE

机译:恒定供热温度的中央供暖系统的液压平衡分析

获取原文
获取原文并翻译 | 示例
           

摘要

In European countries with temperate climates, heating represents approximately 70% of the total energy consumption of a residential building. Different Directives of the European Parliament and Council prescribe the enhancement of energy efficiency and the reduction of energy demand of buildings. Consequently, the control of delivered heat is indispensable. The proper operation of the control system is possible only for balanced central heating systems. In the case of central heating systems with a constant supply temperature, the effects of mass flow deviation on the indoor temperature can be determined using only iterative methods. In this paper, the indoor temperature variation is analyzed for different mass flow deviations, and the effects of unbalancing are analyzed for a refurbished building.
机译:在气候温和的欧洲国家,供暖约占住宅建筑总能耗的70%。欧洲议会和理事会的不同指令规定了提高能源效率和减少建筑物的能源需求。因此,控制所传递的热量是必不可少的。只有平衡的中央供暖系统才能使控制系统正常运行。在中央供暖系统的供水温度恒定的情况下,只能使用迭代方法确定质量流量偏差对室内温度的影响。本文分析了不同质量流量偏差下的室内温度变化,并分析了翻新建筑物的不平衡影响。