首页> 外文期刊>Engineering Structures >Structural perofrmance of shear resisting connections between cold-formed steel sections uisng web cleats fo cold-formed steel strip
【24h】

Structural perofrmance of shear resisting connections between cold-formed steel sections uisng web cleats fo cold-formed steel strip

机译:冷弯型钢使用腹板夹板的冷弯型钢之间抗剪连接的结构性能

获取原文
获取原文并翻译 | 示例
       

摘要

The paper presents an investigation on the structural performance of shear resisting connections between cold-formed steel sections where web cleats of cold-formed steel strips are used to attach beams to supporting beams and columns. A total of 24 connection tests with four different connection configurations were carried out; three modes of failure were identified: failure of fasteners; shear buckling of cold-formed steel web cleats or webs of supported bemas, and; lateral torsional buckling of cold-formed steel web cleats.
机译:本文对冷弯型钢之间的抗剪连接的结构性能进行了研究,其中冷弯型钢的腹板防滑板用于将梁连接到支撑梁和柱上。总共进行了24种具有四种不同连接配置的连接测试。确定了三种故障模式:紧固件故障;冷成型钢网夹板或支撑的bemas板的剪切屈曲,以及冷弯型钢夹板的横向扭转屈曲。