首页> 外文期刊>Engineering Structures >Finite element modeling of bolted connections between coldformed steel strips and hot rolled steel plates under static shear loading
【24h】

Finite element modeling of bolted connections between coldformed steel strips and hot rolled steel plates under static shear loading

机译:静态剪切载荷下冷弯型钢与热轧钢板之间螺栓连接的有限元建模

获取原文
获取原文并翻译 | 示例

摘要

A finite element model with three-dimensional solid elements is established to investigate the structural performance of bolted connections between cold-formed steel strips and hot rolled steel plates udner shear. Non-linear material, geometrical and contact analysis is carried out to predict the load-extension curves of typical bolted connections with cold-formed steel strips of high yield strength and low ductility. The failure mode of interest in the present investigation in the bearing failure of cold-formed steel strip around bolt holes; a full description of the finite element modle is presented. Based on test data, a steel-strain curve for the cold-formed steel strip ois proposed which allows the cold-formed steel strip to yield and degrade in strength at large strain. The load-extension curves of four sets of test specimens were successfully preidicted up to an extension of 3 mm. The predicted bearing resistance and the extensional stiffness of the bolted connections compare well with test data.
机译:建立了三维立体单元的有限元模型,以研究冷弯型钢与热轧钢板之间的螺栓连接的结构性能。进行了非线性材料,几何和接触分析,以预测具有高屈服强度和低延展性的冷弯钢带的典型螺栓连接的载荷-延伸曲线。本研究中关注的失效模式是螺栓孔周围的冷弯型钢的轴承失效。给出了有限元模型的完整描述。根据试验数据,提出了冷弯钢带的钢应变曲线,该曲线允许冷弯钢带在大应变下屈服并降低强度。成功地预测了四组试样的载荷-延伸曲线,直至延伸3 mm。预测的螺栓连接的轴承阻力和延伸刚度与测试数据进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号