首页> 外文期刊>Engineering Structures >Hysteretic behavior of existing an dretrofitted concrete-encased riveted stiffened seat angle connections
【24h】

Hysteretic behavior of existing an dretrofitted concrete-encased riveted stiffened seat angle connections

机译:现有的加装钢筋混凝土的铆接加劲座椅角连接的滞后性能

获取原文
获取原文并翻译 | 示例

摘要

Typical riveted stiffened seat angle connections taken from a 1910 building were tested to investigate their actual hysteretic behavior and potential moment resistance and to determine how they could be efficiently retrofitted with a minimum amount of structural modifications. In that building, columns had been embedded in low-strength concrete, as typically done at the turn of the century as a fireproofing measure, and connections were tested with that fireproofing concrete left in-place. This study shows that, in their as-is conditio, these existing connections can develop a considerable moment resistance, but their pinched hysteretic curves indicate that they have a relatively low energy dissipation capability. Embedment of connections in the concrete is found to be of little benefit.
机译:测试了取自1910年建筑物的典型铆接加劲座椅角连接件,以研究其实际的滞后性能和潜在的抗力矩性能,并确定如何通过最少的结构修改即可有效地对其进行改装。在该建筑物中,圆柱已嵌入低强度混凝土中,这通常是在本世纪初作为防火措施而进行的,并且连接处已使用该防火混凝土进行了测试。这项研究表明,在现有状态下,这些现有的连接可以产生相当大的抗力矩性,但其捏滞的磁滞曲线表明它们具有相对较低的能量耗散能力。发现在混凝土中嵌入连接几乎没有好处。