首页> 外文期刊>Engineering Structures >Earthquake response of tall reinforced concrete chimneys
【24h】

Earthquake response of tall reinforced concrete chimneys

机译:高层钢筋混凝土烟囱的地震反应

获取原文
获取原文并翻译 | 示例
           

摘要

The results from an experimental program have been used to develop a non-linear dynamic analysis procedure for evaluating the inelastic response of tall reinforced concrete chimney structures. The procedure is used to study the inelastic response of ten chimneys, ranging in height from 115 m to 301 m subject to earthquake excitation. Based on the study, a series of code design recommendations have been prepared and incorporated into the 2001 CICIND code to encourage reliance on the development of ductility in reinforced concrete chimneys and to prevent the formation of brittle failure modes. The basis for the selection of a structural response factor of R=2 which halves the seismic design forces is presented. The design recommendations result in both improved performance and cost savings of up to 20% compared with designs undertaken with the 1998 ACI307 and 1998 CICIND codes.
机译:实验程序的结果已用于开发非线性动态分析程序,以评估高层钢筋混凝土烟囱结构的非弹性响应。该程序用于研究10个烟囱在地震激发下的高度从115 m到301 m的非弹性响应。在此研究的基础上,已经准备了一系列规范设计建议,并将其纳入2001 CICIND规范中,以鼓励依靠钢筋混凝土烟囱的延展性发展并防止形成脆性破坏模式。提出了选择将地震设计力减半的R = 2的结构响应因子的基础。与使用1998 ACI307和1998 CICIND代码进行的设计相比,该设计建议可同时提高性能和节省高达20%的成本。