首页> 外文期刊>Engineering Structures >Modified four-hinge mechanism analysis for masonry arches strengthened with near-surface reinforcement
【24h】

Modified four-hinge mechanism analysis for masonry arches strengthened with near-surface reinforcement

机译:近地表加固加固砌体拱的修正四铰机制分析

获取原文
获取原文并翻译 | 示例
           

摘要

A modified mechanism approach to estimate the load capacity of masonry arches strengthened with near-surface reinforcement is presented. This method is developed for reinforced masonry arches failing with a four-hinge mechanism in which measures have been taken to prevent premature failure by ring separation. The analysis takes into account crushing failure of the masonry and yielding of the steel reinforcement. Hinge positions are varied along the arch barrel and their optimum positions are identified when the minimum collapse load is achieved, in accordance with the upper-bound theorem of plasticity. Validation of the proposed method of analysis is carried out by comparing predictions of the load capacity and failure mode with those obtained from large-scale laboratory tests.
机译:提出了一种改进的机制方法来估算近表面加固后的砌体拱的承载能力。这种方法是针对具有四铰链机制而失效的加筋砌体拱门而开发的,在该机制中已采取措施防止环分离引起的过早破坏。该分析考虑了砌体的破碎失败和钢筋的屈服。铰链位置沿拱形炮筒变化,并且根据塑性的上限定理,当达到最小倒塌载荷时,确定其最佳位置。通过将负载能力和失效模式的预测与从大型实验室测试获得的预测进行比较,可以验证所提出的分析方法。