The mutual impacts between two adjacent tall buildings during past major earthquakes have caused significant damage. Researchers have examined the effectiveness of various seismic control devices for interconnecting two adjacent buildings for earthquake hazard mitigation. In this study, the effectiveness of MR damper is examined for seismic response mitigation of adjacent multistory buildings under coupled building control scheme, involving passive-off, passive-on and semiactive control strategies. Further, the influence of damper location and maximum command voltage, on control performance is also examined. Based on the results of the numerical study it has been observed that the MR damper is an effective device to control the response of both the buildings for a wide range of ground motion.
机译:在过去的大地震中,两个相邻的高层建筑之间的相互影响造成了重大破坏。研究人员已经研究了各种地震控制设备将两个相邻建筑物互连以减轻地震危害的有效性。在这项研究中,研究了MR阻尼器在耦合建筑控制方案(包括被动关闭,被动开启和半主动控制策略)下缓解相邻多层建筑物地震响应的有效性。此外,还研究了阻尼器位置和最大指令电压对控制性能的影响。根据数值研究的结果,已经观察到,MR阻尼器是一种有效的装置,可以控制两座建筑物在大范围的地面运动中的响应。