首页> 外文期刊>Engineering Structures >Collapse modelling analysis of a precast soft storey building in Australia
【24h】

Collapse modelling analysis of a precast soft storey building in Australia

机译:澳大利亚预制软层建筑物的倒塌建模分析

获取原文
获取原文并翻译 | 示例
           

摘要

A unique experimental field test study that provides insight into the push-over load-deflection and collapse behaviour of a soft storey building is reported in this paper. The five storey building had been identified as being particularly vulnerable to earthquake excitation due to the particularly weak connections at each end of the ground floor precast columns that constituted the soft storey. Consequently, four field tests were undertaken to investigate the actual lateral force-deflection behaviour of the soft storey columns. Interestingly, the tests indicated that the soft storey columns possessed significant displacement capacity despite significant strength degradation. An analytical model developed to predict the overall force-displacement relationship that was influenced by the three component mechanisms of (a) connection strength at column ends, (b) gravity rocking strength and (c) ground slab interaction, was found to be in excellent agreement with the experimental test results. The presence of the 'non-structural' ground slab provided additional lateral strength to the system and greatly influenced the 'as-built' performance. The displacement capacity of the precast soft storey system was much greater than an equivalent in situ system, due to the rigid body rocking behaviour of the columns. The precast soft storey system was found to have sufficient displacement capacity for lower seismic regions, but the performance was considered marginal for higher seismic regions.
机译:本文报道了一项独特的实验现场测试研究,该研究提供了对软层建筑物的推覆荷载变形和倒塌行为的洞察力。由于构成软层的地下预制柱各端的连接处特别脆弱,因此已确定该五层建筑物特别容易受到地震的影响。因此,进行了四个现场测试,以研究软层柱的实际横向力-挠度行为。有趣的是,测试表明,尽管强度明显下降,软层柱仍具有明显的置换能力。发现一种分析模型可以预测整体受力-位移关系,该模型受以下三个因素机制的影响:(a)柱端的连接强度,(b)重力摇摆强度和(c)楼板相互作用。与实验测试结果吻合。 “非结构”地面板的存在为系统提供了额外的横向强度,并极大地影响了“竣工”性能。预制软层系统的位移能力比等效的原位系统大得多,这归因于柱体的刚性摇摆特性。已发现预制软层系统对于较低地震区域具有足够的位移能力,但对于较高地震区域,该性能被认为是微不足道的。

著录项

  • 来源
    《Engineering Structures》 |2010年第7期|1925-1936|共12页
  • 作者单位

    Faculty of Engineering and Industrial Sciences, Swinburne University of Technology, Victoria, 3122, Australia;

    rnFaculty of Engineering and Industrial Sciences, Swinburne University of Technology, Victoria, 3122, Australia;

    Department of Civil & Environmental Engineering, University of Melbourne, Victoria, 3010, Australia;

    rnFaculty of Engineering and Industrial Sciences, Swinburne University of Technology, Victoria, 3122, Australia Department of Civil & Environmental Engineering, University of Melbourne, Victoria, 3010, Australia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    precast concrete; soft storey structure; force-displacement relationship; earthquake performance;

    机译:预制混凝土软层结构;力-位移关系;地震表现;