摘要

In the last few decades, the use of cast in situ reinforced concrete sandwich panels for the construction of low- to mid-rise buildings has become more and more widespread due to several interesting properties of this construction technique, such as fast construction and high thermal and acoustic performances. Nonetheless the level of knowledge of the structural behavior of systems made of squat reinforced concrete sandwich panels is still not so consolidated, especially with reference to the seismic response, due to the lack of experimental studies. In recent years, while various experimental tests have been conducted on single panels aimed at assessing their seismic capacity, only few tests have been carried out on more complex structural systems. In this paper, the experimental results of a series of shaking-table tests performed on a full-scale 3-storey building are presented in detail. The main goal is to give to the scientific community the possibility of develop independent interpretation of these experimental results. An in-depth interpretation of the discrepancies between the analytical predictions and the experimental results is beyond the objective of this paper and is still under development. Nonetheless, preliminary interpretations indicate that both the stiffness and the strength of the building under dynamic excitation appear quite superior with respect to those expected from the results of previous pseudo-static cyclic tests conducted on simple specimens.
机译:在过去的几十年中,由于这种建造技术的一些有趣的特性,例如快速建造和高耐热性,在中低层建筑中使用现浇钢筋混凝土夹芯板已变得越来越普遍。和声学表演。然而,由于缺乏实验研究,关于蹲式钢筋混凝土夹芯板制成的系统的结构行为的知识水平仍未得到充分巩固,特别是在地震响应方面。近年来,虽然已经在单个面板上进行了各种实验测试以评估其抗震能力,但在更复杂的结构系统上仅进行了很少的测试。在本文中,详细介绍了在一个完整的三层楼建筑物上进行的一系列振动台测试的实验结果。主要目标是使科学界有可能对这些实验结果进行独立的解释。对分析预测与实验结果之间差异的深入解释超出了本文的目的,并且仍在开发中。尽管如此,初步解释表明,在动态激励下,建筑物的刚度和强度都比以前对简单样本进行的拟静力循环试验的结果所期望的要好。

著录项

  • 来源
    《Engineering Structures》 |2014年第1期|75-89|共15页
  • 作者单位

    Department DICAM, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy;

    Department DICAM, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy;

    Department DICAM, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy;

    Department DICAM, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy;

    Department DICAM, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy;

    Department DICA, Politecnico of Bari, Via E. Orabona, 4, 70125 Bari, Italy;

    Department DIC, University of Alicante, Carretera San Vicente del Raspeig, 03690 San Vicente del Raspeig, Alicante, Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Reinforced concrete sandwich panels; Polystyrene; Mid-rise building; Shaking-table tests;

    机译:钢筋混凝土夹芯板;聚苯乙烯中层建筑;振动台测试;