首页> 外文期刊>Engineering Structures >Analysis of partially composite foam insulated concrete sandwich structures
【24h】

Analysis of partially composite foam insulated concrete sandwich structures

机译:部分复合泡沫保温混凝土夹芯结构分析

获取原文
获取原文并翻译 | 示例

摘要

This paper presents the theoretical development that defines the small displacement behavior of foam insulated concrete sandwich panels. Composite theories presented by other researchers are first thoroughly reviewed and scrutinized in the context of their use for precast concrete beams. A more rigorous Discrete Model that incorporates the complex shear deformation behaviors and independent flexural resistance of the concrete wythes is then derived. Experimental data from full-scale precast sandwich panel tests are used to validate the developed methodology. Finally, it is demonstrated that this study provides a rigorous analysis methodology for foam insulated concrete sandwich structures. (C) 2015 Elsevier Ltd. All rights reserved.
机译:本文介绍了理论发展,它定义了泡沫绝缘混凝土夹芯板的小位移行为。首先,对其他研究人员提出的复合理论进行了彻底的审查和审查,以将其用于预制混凝土梁。然后,得出了一个更严格的离散模型,该模型结合了复杂的剪切变形行为和独立的混凝土抗弯强度。来自全尺寸预制夹心板测试的实验数据用于验证开发的方法。最后,证明该研究为泡沫绝缘混凝土夹层结构提供了严格的分析方法。 (C)2015 Elsevier Ltd.保留所有权利。