首页> 外文期刊>Engineering Structures >Strengthening system using post-tension tendon with an internal anchorage of concrete members
【24h】

Strengthening system using post-tension tendon with an internal anchorage of concrete members

机译:使用后张力筋和混凝土构件内部锚固的加固系统

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The present study aims to develop a strengthening system using prestressing tendons embedded into an internal anchorage of concrete member. The internal anchorage, a wedge-shaped hole, is made by using a special drilling machine. The tip of the hole is filled with high strength mortar to anchor firmly the prestressing tendon. The strengthening system is acceptable even in relatively narrow workspaces, and also applicable for joints between existing and additional concrete members. The experimental study conducted a pull-out test of the prestressing tendon to examine the load-bearing capacity. A finite element simulation was also performed to confirm the bonding and unbonding effects of the prestressing tendon. The test result confirms adequate load-bearing capacity of the anchorage for the prestressing tendon. In addition, the FE simulation shows that the strengthening system can provide a constant prestress even if the prestressing tendon is not bound to the mortar in the anchorage. (C) 2016 Elsevier Ltd. All rights reserved.
机译:本研究旨在开发一种利用预应力筋嵌入混凝土构件内部锚固中的加固系统。内部锚固是一个楔形孔,是使用特殊的钻孔机制成的。孔的尖端填充有高强度砂浆,可以牢固地锚固预应力筋。即使在相对狭窄的工作空间中,加固系统也是可以接受的,并且也适用于现有混凝土构件与其他混凝土构件之间的连接。实验研究对预应力筋进行了拉拔测试,以检查承载能力。还进行了有限元模拟,以确认预应力筋的粘结和非粘结效果。测试结果证实了预应力筋具有足够的承重能力。此外,有限元模拟表明,即使预应力筋没有与锚固中的砂浆粘结,加固系统也可以提供恒定的预应力。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Engineering Structures》 |2016年第1期|29-35|共7页
  • 作者单位

    Yamaguchi Univ, Dept Civil & Environm Engn, 2-16-1 Tokiwadai, Ube, Yamaguchi 7558611, Japan|Kyokuto Kowa Corp, Higashi Ku, Hikarimachi 2-6-31, Hiroshima, Hiroshima 7320052, Japan;

    Yamaguchi Univ, Dept Civil & Environm Engn, 2-16-1 Tokiwadai, Ube, Yamaguchi 7558611, Japan;

    Kyokuto Kowa Corp, Higashi Ku, Hikarimachi 2-6-31, Hiroshima, Hiroshima 7320052, Japan;

    Yamaguchi Univ, Dept Civil & Environm Engn, 2-16-1 Tokiwadai, Ube, Yamaguchi 7558611, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Internal anchorage; Strengthening; Prestressing tendon; Pull-out test;