首页> 外文期刊>Engineering Structures >Spalling in concrete subjected to shock wave blast
【24h】

Spalling in concrete subjected to shock wave blast

机译:遭受冲击波爆炸的混凝土剥落

获取原文
获取原文并翻译 | 示例

摘要

This paper studies the response in a concrete wall subjected to shock wave blast, leading to spalling failure. This situation is important since spalled-off fragments in protective structures may cause severe injury to the persons or equipment it is supposed to protect. Many theoretical expressions indicates that spalling occurs when and where the tensile strength of a strain-softening material like concrete is reached regardless of the time duration of the applied load. By using a simple uni-axial numerical model, this study shows that spalling instead might occurs when the cyclic response from a blast wave gradually increase the inelastic strains in the concrete. This means that spalling takes place after several loading cycles and not necessarily at the depth where tensile strength is firstly reached. Furthermore, the study shows that the cyclic response in the material model used for numerical simulation has a decisive influence on the position and extent of the resulting spalling crack. (C) 2016 Elsevier Ltd. All rights reserved.
机译:本文研究了遭受冲击波爆炸而导致剥落破坏的混凝土墙的响应。这种情况很重要,因为保护结构中散落的碎片可能会对应该保护的人员或设备造成严重伤害。许多理论表达式表明,当达到诸如混凝土之类的应变软化材料的拉伸强度时,无论施加载荷的持续时间如何,均会发生剥落。通过使用简单的单轴数值模型,该研究表明,当爆炸波的循环响应逐渐增加混凝土中的非弹性应变时,可能会发生剥落。这意味着在几次加载循环后会发生剥落,而不一定在首次达到抗拉强度的深度发生。此外,研究表明,用于数值模拟的材料模型中的循环响应对产生的散裂裂纹的位置和程度具有决定性的影响。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号