Splicing method of bending elements is important for the restoration of ancient timber structures due to the principle of preserving as much as possible the original material. This study investigates the flexural performance of spliced beams connected and reinforced with self-tapping wood screws. An experimental program based on four-point bending test configuration was conducted to examine the strength, stiffness and ductility of spliced beams. The test results showed that the spliced beams' average ultimate bending capacity reached 59.5% of the size and load duration adjusted specified bending capacity of the intact beam. Their stiffness achieved 64.3% of the specified design value in Canadian Wood Design Manual. The spliced beams experienced head pull-through failure of the self-tapping screws. This failure mode led to ductile behavior different from the typical tension failure mode of the wood fibers in glulam beam. Based on the experimental results, an analytical model that addressed the specific head pull-through failure mode was proposed to predict the flexural capacity of spliced beams. The analytical model was calibrated by the data of the head pull-through resistance test results and verified by full-size tests. Comparisons of the analytical and the test results reveal that the model can adequately predict the moment capacity of the spliced beams with the corresponding specific failure mode. (C) 2017 Published by Elsevier Ltd.
机译:由于尽可能保留原始材料的原理,弯曲元件的拼接方法对于古代木结构的修复很重要。本研究调查了用自攻木螺钉连接和加固的拼接梁的抗弯性能。进行了基于四点弯曲测试配置的实验程序,以检查拼接梁的强度,刚度和延性。测试结果表明,拼接梁的平均极限抗弯能力达到尺寸的59.5%,荷载持续时间调整了完整梁的指定抗弯能力。其刚度达到了《加拿大木材设计手册》中指定设计值的64.3%。拼接梁经历了自攻螺钉的头部穿透故障。这种破坏模式导致延展性能不同于胶合木梁中木纤维的典型拉伸破坏模式。基于实验结果,提出了一种针对特定磁头穿通失效模式的分析模型,以预测拼接梁的抗弯能力。通过磁头抗拉测试结果的数据对分析模型进行校准,并通过全尺寸测试进行验证。分析结果和测试结果的比较表明,该模型可以充分预测具有相应特定破坏模式的拼接梁的弯矩承载力。 (C)2017由Elsevier Ltd.发布

著录项

  • 来源
    《Engineering Structures》 |2017年第1期|523-534|共12页
  • 作者单位

    Southeast Univ, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct Ch, Nanjing 210096, Jiangsu, Peoples R China;

    Univ British Columbia, Dept Wood Sci, 2424 Main Mall, Vancouver, BC V6T 1Z4, Canada;

    Southeast Univ, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct Ch, Nanjing 210096, Jiangsu, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Spliced beam; Capacity; Stiffness; Ductility; Analytical model; Full thread self-tapping screws;

    机译:拼接梁;容量;刚度;延性;分析模型;全螺纹自攻螺钉;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号