首页> 外文期刊>Engineering Structures >Cyclic behavior of damaged reinforced concrete columns repaired with high-performance fiber-reinforced cementitious composite
【24h】

Cyclic behavior of damaged reinforced concrete columns repaired with high-performance fiber-reinforced cementitious composite

机译:高性能纤维增强水泥基复合材料修复受损钢筋混凝土柱的循环特性

获取原文
获取原文并翻译 | 示例
           

摘要

A high-performance fiber-reinforced cementitious composite (HPFRCC) prepared with high-volume fly ash is proposed to repair damaged reinforced concrete (RC) columns. This study aims at developing an effective and easy-to-apply repairing technique for RC columns damaged in earthquake. Four columns with 200 mm x 200 mm cross section and 900 mm height were prepared and tested to 85% of the load-carrying capacity under amplitude-increasing lateral loads and a constant axial load. The damaged columns were repaired using the HPFRCC: two repair heights (300 and 500 mm) and two repairing processes (with and without axial loads). The effectiveness of the repairing schemes was evaluated by comparing load-carrying capacities, displacement ductility, stiffness, and energy dissipation of the columns. The results indicated that the load-carrying capacity and ductility of the repaired columns could be respectively 14% and 29% higher than those of the original columns. With axial loads during repairing, the repaired columns displayed better cyclic performance. Increasing the repair height beyond the plastic hinge zone slightly improved the load-carrying capacity and ductility. Considering the performance-to cost ratio, it is recommended that the repair height of HPFRCC be 1.5 times the depth or width of the damaged column. (C) 2017 Elsevier Ltd. All rights reserved.
机译:提出了一种用大量粉煤灰制备的高性能纤维增强水泥基复合材料(HPFRCC),以修复受损的钢筋混凝土(RC)柱。这项研究旨在为地震中受损的钢筋混凝土柱开发一种有效且易于应用的修复技术。准备了四个截面为200 mm x 200 mm,高度为900 mm的圆柱,并在振幅增加的横向载荷和恒定的轴向载荷下测试了其承载能力的85%。损坏的色谱柱使用HPFRCC进行了修复:两个修复高度(300和500 mm)和两个修复过程(有和没有轴向载荷)。通过比较柱的承载能力,位移延展性,刚度和能量耗散,评估了修复方案的有效性。结果表明,修复后的柱子的承载能力和延性分别比原始柱子高14%和29%。在修复过程中承受轴向载荷时,修复后的柱子表现出更好的循环性能。将修理高度增加到塑料铰链区域以外的地方,可以略微改善承载能力和延展性。考虑到性能成本比,建议HPFRCC的维修高度为损坏色谱柱的深度或宽度的1.5倍。 (C)2017 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Engineering Structures》 |2017年第1期|26-35|共10页
  • 作者单位

    Coinnovat Ctr Green Bldg, Jinan 250101, Shandong, Peoples R China|Shandong Jianzhu Univ, Sch Civil Engn, Jinan 250101, Shandong, Peoples R China|Missouri Univ Sci & Technol, Dept Civil Architectural & Environm Engn, Rolla, MO 65409 USA;

    Shandong Jianzhu Univ, Sch Civil Engn, Jinan 250101, Shandong, Peoples R China;

    Missouri Univ Sci & Technol, Dept Civil Architectural & Environm Engn, Rolla, MO 65409 USA;

    Missouri Univ Sci & Technol, Dept Civil Architectural & Environm Engn, Rolla, MO 65409 USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Repair; Reinforced concrete column; Cyclic behavior; Loading effect; High-performance fiber-reinforced; cementitious composite (HPFRCC);

    机译:修复;钢筋混凝土柱;循环性能;荷载作用;高性能纤维增强;胶凝复合材料(HPFRCC);

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号