首页> 外文期刊>Engineering Structures >Axial load transfer in non-slender ultra-high-strength concrete columns through normal-strength concrete floor slabs
【24h】

Axial load transfer in non-slender ultra-high-strength concrete columns through normal-strength concrete floor slabs

机译:非细长超高强度混凝土柱通过普通强度混凝土楼板的轴向荷载传递

获取原文
获取原文并翻译 | 示例

摘要

Three slab-column specimens, which represent interior, edge, and corner connections, and three isolated column specimens were tested to investigate the axial load transfer in non-slender ultra-high-strength concrete (UHSC, f(c)(') approximate to 200 MPa) columns through normal-strength concrete (NSC, f(c)(') approximate to 50 MPa) slabs. The test results showed that the confinement of the slab-column joint from the surrounding slab increased the axial capacity of the column even though the column strength (f(c)(') approximate to 200 MPa) as well as the ratio of the column concrete strength to the slab concrete strength (f(cc)(')/f(cs)(') approximate to 4.0) are very high. This strength enhancement is a function of the degree of joint confinement provided by the surrounding slab, and even corner slab-column connections showed some degree of strength enhancement. The experimental results from this study and from other researchers were also compared with current code approaches in the ACI Code (ACI 318-14) and CSA Standard (CSA A23.3-14). These approaches were found to be conservative and hence represent lower bound predictions for design purposes for corner and edge slab-column connections. It was found that the ACI Code approach can give unconservative predictions for interior slab-column connections for cases with the slab carrying loads. The CSA Standard approach provides reasonable lower bound predictions for interior slab-column connections, even for cases where the slab is loaded. (C) 2017 Elsevier Ltd. All rights reserved.
机译:测试了三个表示内部,边缘和角部连接的板柱标本和三个隔离的柱标本,以研究非细长超高强度混凝土的轴向载荷传递(UHSC,f(c)(')近似)到200 MPa)的柱子通过普通强度的混凝土(NSC,f(c)(')约为50 MPa)平板。试验结果表明,即使柱的强度(f(c)(')约为200 MPa)和柱的比率,从周围的板到柱-柱的约束也会增加柱的轴向承载力。相对于平板混凝土的混凝土强度(f(cc)(')/ f(cs)(')约为4.0)非常高。这种强度增强是周围平板所提供的接缝约束程度的函数,甚至角平板-柱连接也显示出一定程度的强度增强。这项研究和其他研究人员的实验结果也与ACI代码(ACI 318-14)和CSA标准(CSA A23.3-14)中的当前代码方法进行了比较。这些方法被认为是保守的,因此代表了角和边平板-柱连接的设计目的的下界预测。已经发现,对于带有承重板的情况,ACI规范方法可以为内部板-柱连接提供非保守的预测。 CSA标准方法为内部平板-柱连接提供了合理的下限预测,即使是在加载平板的情况下。 (C)2017 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号