Collapse performance of seismically isolated buildings designed by the procedures of ASCE/SEI 7

机译:按照ASCE / SEI 7程序设计的地震隔离建筑物的倒塌性能

获取原文
获取原文并翻译 | 示例
           

摘要

This article presents an analytical study of the seismic collapse performance of seismically isolated buildings and comparable non-isolated buildings. The study is based on archetypical 6-story perimeter frame seismically isolated buildings designed with special concentrically braced frames (SCBF), ordinary concentrically braced frames (OCBF) and special moment resisting frames (SMF) for a location in California using the minimum criteria of ASCE/SEI 7-10 and ASCE/SEI 7-16 and also using a number of enhanced designs. The isolation system consists of triple Friction Pendulum (FP) isolators with stiffening behavior at large displacement. Additionally, double concave sliding isolators are considered and designed per minimum criteria of ASCE/SEI 7 and without a displacement restrainer, a practice permitted by the standards. Non-isolated structures, also with braced and moment frame configurations, are designed using the minimum criteria of ASCE/SEI 7 and studied. The study concludes that seismically isolated buildings designed by the minimum criteria of ASCE/SEI 7 of either 2010 or 2016 may have unacceptable probability of collapse in the Risk-Targeted Maximum Considered Earthquake (MCER). The probability of collapse in the MCER becomes acceptable when they are designed with enhanced criteria of R-I = 1.0 and with isolators having a displacement capacity at initiation of stiffening equal to 1.5 times the demand in the MCER. It is also observed that designs that meet the minimum criteria of ASCE/SEI 7 of either 2010 or 2016 and without any displacement restrainer have unacceptably high probabilities of collapse.
机译:本文介绍了对地震隔离建筑物和可比较的非隔离建筑物的地震倒塌性能的分析研究。这项研究基于在加利福尼亚某地区使用ASCE的最低标准设计的典型6层周长框架地震隔离建筑物,这些建筑物设计有特殊的同心支撑框架(SCBF),普通的同心支撑框架(OCBF)和特殊的抗弯框架(SMF) / SEI 7-10和ASCE / SEI 7-16,并且还使用了许多增强设计。隔离系统由三重摩擦摆锤(FP)隔离器组成,在大位移时具有加强性能。此外,根据ASCE / SEI 7的最低标准考虑并设计了双凹面滑动隔离器,并且没有位移限制器,这是标准允许的做法。使用ASCE / SEI 7的最低标准设计并研究了具有支撑和弯矩框架配置的非隔离结构,并进行了研究。该研究得出的结论是,按照2010年或2016年ASCE / SEI 7最低标准设计的地震隔离建筑物在以风险为导向的最大考虑地震(MCER)中可能会坍塌,这是不可接受的。当使用增强的标准R-1 = 1.0且隔离器刚开始时位移能力等于MCER要求的1.5倍的隔离器设计时,MCER发生坍塌的可能性就可以接受。还可以观察到,满足2010年或2016年ASCE / SEI 7最低标准且没有任何位移限制器的设计,坍塌的可能性很高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号