首页> 外文期刊>Engineering Structures >Push-out test on the web opening shear connector for a slim-floor steel beam: Experimental and analytical study
【24h】

Push-out test on the web opening shear connector for a slim-floor steel beam: Experimental and analytical study

机译:轻型钢梁腹板开口剪力连接器的推出试验:实验和分析研究

获取原文
获取原文并翻译 | 示例

摘要

In slim-floor construction, the web opening of the steel beam is proposed as WO shear connectors of different shapes; square (WSO), rectangular (WRO) and circular (WCO) connectors were considered to evaluate the ultimate shear strength, failure mode and ductility performance. Six push-out tests were conducted under static loading. Finite Element (FE) models using ABAQUS software were validated using test results, and then, further models were developed. The effective parameters include web thickness of the steel beam, opening size, compressive strength of the concrete slab and group arrangement for WO connectors. The test result indicates higher shear strength for the WSO shear connector compared with WRO and WCO. FE analysis presents notable shear achievement of WSO and WRO connectors because of the larger effective width of the square and rectangular openings incorporated with infill concrete. Thicker web steel beam associated with larger opening enhanced the compressive and tensile resistance area of the infill concrete in all cases. The effective spacing between group WCO shear connectors was found to be 250 mm, and it was found to be 300 mm for WSO and WRO to achieve maximum shear strength. Finally, the ultimate shear resistance of the WCO and WSO/WRO shear connectors were predicted and validated with COV of 0.032 and 0.021, respectively.
机译:在超薄结构中,建议将钢梁的腹板开口用作不同形状的WO剪切连接器。考虑使用方形(WSO),矩形(WRO)和圆形(WCO)连接器来评估极限剪切强度,破坏模式和延展性能。在静态载荷下进行了六次推出测试。使用测试结果验证了使用ABAQUS软件的有限元(FE)模型,然后开发了进一步的模型。有效参数包括钢梁的腹板厚度,开口尺寸,混凝土板的抗压强度以及WO连接器的组布置。测试结果表明,与WRO和WCO相比,WSO剪切连接器的剪切强度更高。有限元分析表明WSO和WRO连接器具有显着的剪切效果,因为与填充混凝土结合的方形和矩形开口的有效宽度更大。在任何情况下,较厚的腹板钢梁和较大的开口都会增加填充混凝土的抗压和抗拉面积。发现WCO组剪切连接器之间的有效间距为250 mm,WSO和WRO为获得最大剪切强度而发现的有效间距为300 mm。最后,预测并验证了WCO和WSO / WRO剪切连接器的极限抗剪强度,其COV分别为0.032和0.021。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号