首页> 外文期刊>Engineering Structures >UHPC sandwich panels with GFRP shear connectors tested under combined bending and axial loads
【24h】

UHPC sandwich panels with GFRP shear connectors tested under combined bending and axial loads

机译:具有GFRP剪切连接器的UHPC夹层面板在组合弯曲和轴向载荷下进行测试

获取原文
获取原文并翻译 | 示例

摘要

A new design of double wythe insulated wall panels using ultra-high performance concrete (UHPC) and glass fibre-reinforced polymer (GFRP) shear connectors is developed and tested. It consists of two 25 mm thick UHPC ribbed wythes with a 152 mm thick layer of extruded polystyrene (XPS) sandwiched in between. Small diameter (4 mm) GFRP bars were used as reinforcements in the wythes and as diagonal shear connectors. Five 3.0 x 0.61 x 0.2 m panels were tested to failure in flexure (M), under axial compression (P) and under combined loading. Four-point bending was used to simulate wind pressure, while axial compression was applied on one wythe only, representing gravity floor loading. For combined loading, a constant (P) of 16%, 33% or 66% of the axial strength of the wall was applied on three different panels, then transverse loading was applied to failure. The full (P-M) interaction curves, relative to the centroids of a composite and non-composite sections were developed, including both primary and secondary moments from slenderness. The degree of composite action was calculated to be 78% under transverse loading only and was reduced as the axial load increased. Failure was triggered by a progressive fracture of the diagonal GFRP shear connectors, regardless of the M and P combination. The wall design met serviceability requirements at the highest wind pressure based on the 50-year return period as per the National Building Code of Canada.
机译:使用超高性能混凝土(UHPC)和玻璃纤维增​​强聚合物(GFRP)剪切连接器的新型双人无线隔离墙板设计的新设计。它由两个25毫米厚的UHPC罗纹有关的Wyth,其中152mm厚的挤出聚苯乙烯(XPS)层夹在两者之间。小直径(4mm)GFRP棒用作WYTHES中的增强件和对角线剪切连接器。在轴向压缩(P)下,在弯曲(m)下,测试5.0×0.61×0.2M面板在弯曲(m)下,并在组合加载下。使用四点弯曲来模拟风压,而轴向压缩仅适用于唯一的Wythe,代表重力地板载荷。对于组合负载,在三个不同的面板上施加壁的轴向强度的16%,33%或66%的恒定(P),然后将横向载荷施加到失效中。相对于复合材料和非复合部分的质心的完全(P-M)相互作用曲线,包括来自细长的初级和次要时刻。在横向加载下计算复合作用程度为78%,随着轴向载荷的增加而降低。无论M和P组合如何,由对角线GFRP剪切连接器的渐进式断裂触发失败。根据加拿大国家建筑码,基于50年回报期,墙面设计满足最高风力压力的可维护性要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号