摘要

The concrete-encased concrete-filled steel tubular (CFST) columns are usually connected to steel beams in structures. In this study, a total of nine different connection details are proposed for the steel beam to concrete-encased CFST column composite joints, and their structural behavior under seismic loading was evaluated experimentally. The failure patterns, the hysteretic load-displacement relations, moment-curvature relations and the strain responses of these joints were recorded and compared. It was found that joints with the external diaphragm and through-beam details had the most convenient seismic performance among these joints.
机译:装有混凝土的钢管混凝土柱(CFST)通常与结构中的钢梁连接。在这项研究中,共提出了九种不同的连接细节,用于钢梁与混凝土包裹的CFST柱组合节点,并通过试验评估了它们在地震荷载下的结构性能。记录并比较了这些接头的破坏模式,滞后载荷-位移关系,弯矩-曲率关系以及应变响应。结果发现,在这些接头中,具有外部膜片和贯通梁细节的接头具有最方便的抗震性能。