Most existing formulations for determining shear strength due to web-post buckling by shear (WPBS) in castellated steel beams depend on many variables, are not applicable to fire situation or do not have a normative approach. In order to provide a simpler and more practical formulation, also applicable to the fire situation, this study presents a semi-empirical formulation based on numerical results of validated models, considering the hypothesis of uniform temperature distribution along the profile and the analogy between the strut model and the compressed diagonal of a web-post subject to WPBS. This semi-empirical model is based on the formulation of EN 1993-1-2:2005 and ABNT NBR 14323:2013 to obtain the resistance of compressed members at elevated temperatures and it is applicable to Litzka, anglo-saxon and Peiner type castellated beams.
机译:用于确定钢形梁中由于剪力作用引起的腹板后屈曲(WPBS)的剪切强度的大多数现有公式取决于许多变量,不适用于火灾情况或没有规范性方法。为了提供更简单,更实用的公式,也适用于火灾情况,本研究基于经过验证的模型的数值结果提出了一种半经验公式,其中考虑了沿剖面均匀温度分布的假设以及支杆之间的类比。模型和受WPBS约束的网络发布的压缩对角线。此半经验模型基于EN 1993-1-2:2005和ABNT NBR 14323:2013的公式来获得压缩构件在高温下的抵抗力,并且适用于Litzka,盎格鲁-撒克逊人和Peiner型cast形梁。