首页> 外文期刊>Engineering Structures >A finite element study of welded aluminum shoe-base light pole details
【24h】

A finite element study of welded aluminum shoe-base light pole details

机译:焊接铝制鞋底灯杆细节的有限元研究

获取原文
获取原文并翻译 | 示例
           

摘要

Cantilevered light poles are examples of lightly damped, slender structural systems subjected to wind (cyclic) loads making fatigue life analysis necessary. Experimental and numerical studies performed on welded aluminum shoe-base details often found on cantilevered light poles included thirty-five fatigue tested in the Structures Laboratory of the University of Akron that provided the basis for the analytical study described in this article. Twenty-two of the thirty-five specimens failed and the remainder taken as run-outs. In an attempt to understand the fatigue behavior of the welded aluminum details, parametric studies using ANSYS examined bolt circle diameter, fillet weld leg-size, socket depth, and tube thickness. An increase in the bolt circle diameter of 27% results in about a 50% increase in the local stress adjacent to the fillet weld, and a reduction in tip deflection. A 50% increase in the fillet weld leg-size from 6.35 mm (0.25 in.) to 9.5 mm (0.375 in.) corresponds to about a 14% increase in the local stress. Increasing the shoe-base socket depth by 51% leads to an increase of 36% in the local stress. An increase in the thickness of 40% from 6.35 mm (0.25 in.) to 8.9 mm (0.35 in.) reflects a 60% increase in local stress. The analysis demonstrated that the lowest factor of safety was observed adjacent to the toe of the fillet weld. Thermographic measurements confirmed the existence of a hot spot near the weld toe on the tube.
机译:悬臂灯杆是承受风(循环)载荷的轻阻尼,细长结构系统的示例,因此需要进行疲劳寿命分析。对在悬臂灯杆上经常发现的焊接铝制鞋底细节进行的实验和数值研究包括在阿克伦大学结构实验室进行的35个疲劳测试,为本文所述的分析研究提供了基础。在35个标本中,有22个失败了,其余的则作为跳动。为了理解铝焊接细节的疲劳行为,使用ANSYS进行参数研究研究了螺栓的圆直径,角焊缝支脚尺寸,承插口深度和管厚。螺栓圆直径增加27%,会使角焊缝附近的局部应力增加约50%,并减小尖端变形。角焊焊脚尺寸从6.35毫米(0.25英寸)增加到9.5毫米(0.375英寸)增加了50%,相当于局部应力增加了约14%。将鞋底插座深度增加51%,导致局部应力增加36%。厚度从6.35毫米(0.25英寸)增加到8.9毫米(0.35英寸)增加了40%,反映了局部应力增加了60%。分析表明,在角焊缝趾部附近观察到最低的安全系数。热像仪测量结果证实了管上焊趾附近存在热点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号