The paper provides an insight into the seismic strengthening of masonry towers by means of horizontal and vertical steel tie-rods. The approach is based on the kinematic theorem of limit analysis with pre-assigned failure mechanisms. Among all the possible ones, five of them commonly observed during post-earthquake surveys are selected: (#1) vertical splitting; (#2) base rocking; (#3) Heyman��s diagonal rocking; (#4) combination of splitting and diagonal rocking; (#5) base sliding. The aim is to put at disposal a procedure that can be used in any case of technical interest. To provide general output applicable in different contexts, towers are supposed isolated and idealized with a constant hollow square cross-section, without openings and any type of irregularity. Different mechanisms can be activated as a consequence of geometric features (base, height and thickness of the walls) and masonry mechanical properties, here assumed obeying a Mohr-Coulomb failure criterion. Thanks to the simplicity of the approach, comprehensive sensitivity analyses with different heights, base widths and wall thicknesses varying in the range of technical interest, as well as large scale Monte Carlo (MC) simulations with several geometries and three different sets of mechanical properties are carried out. The possible introduction of horizontal and vertical steel tie-rods is investigated in the same way, simply considering the contribution of the reinforcement in the internal dissipation in limit analysis computations. The results of the analyses show that, depending on the geometry of the tower and the mechanical properties of masonry, different mechanisms can be activated and therefore the choice of the reinforcement must be done on the basis of the expected failure mode. In addition, it is possible to predict the change in the active failure mechanism due to the introduction of reinforcement, as well as to evaluate the increase in the load carrying capacity.
机译:本文通过水平和垂直钢拉杆提供了对砌体塔的抗震加固的见解。该方法基于具有预先指定的失效机制的极限分析运动定理。在所有可能的方法中,选择了五个在地震后调查中通常观察到的方法:(#1)垂直分裂; (#2)基础摇摆; (#3)海曼的对角摇摆; (#4)分裂和对角摇摆的组合; (#5)基础滑动。目的是要处置一种可以在任何技术利益的情况下使用的程序。为了提供适用于不同环境的一般输出,假定塔是隔离的,理想的是具有恒定的空心正方形横截面,没有开口和任何类型的不规则性。由于几何特征(墙的基础,高度和厚度)和砌体机械性能(在此假设遵循Mohr-Coulomb破坏准则),可以激活不同的机制。由于该方法的简单性,可以对具有不同高度,基础宽度和壁厚的全面灵敏度分析(在技术关注范围内有所变化)以及具有几种几何形状和三组不同机械性能的大规模蒙特卡洛(MC)模拟进行分析执行。只需考虑极限分析计算中钢筋对内部耗散的贡献,就可以以相同的方式研究水平和垂直钢拉杆的可能引入。分析结果表明,根据塔架的几何形状和砌体的机械性能,可以激活不同的机制,因此必须根据预期的破坏模式来选择钢筋。此外,可以预测由于引入钢筋而导致的主动破坏机制的变化,并可以评估承载能力的提高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号