Discussion addresses the vibration responses of a large glued-laminated-timber (glulam) beam-and-deck system subjected to office floor loadings. Ambient Vibration Test (AVT) was carried out before floor topping layers were added, and after occupation of the building. Addition of topping layers, and presence of office workers and furniture strongly influenced the fundamental frequency and damping of the system. Detailed Finite Element (FE) models were created. It was found that only FE analyses that exceed 'typical' design approach would provide an accurate model. Controlled walking tests associated with normal office activities were conducted. Those indicated the particular floor, and possibly other large glulam beam-and-deck floors with concrete topping, is not prone to low level vibration serviceability problems.
机译:讨论的内容是承受办公室地板负荷的大型胶合层压木(胶合木)梁和甲板系统的振动响应。在添加地板顶层之前和建筑物占用之后进行了环境振动测试(AVT)。顶层的添加以及上班族和家具的出现强烈影响了系统的基本频率和阻尼。创建了详细的有限元(FE)模型。发现只有超出“典型”设计方法的有限元分析才能提供准确的模型。进行了与正常办公室活动有关的受控步行测试。那些指出特定的地板,以及可能还有其他带有混凝土顶部的大胶合木横梁和甲板地板,不容易出现低水平的振动维修性问题。