首页> 外文期刊>Engineering Structures >Seismic performance improvement of tension-only-braced frames with Energy-Dissipative Rocking Columns
【24h】

Seismic performance improvement of tension-only-braced frames with Energy-Dissipative Rocking Columns

机译:耗能摇摆柱改善了仅张拉支撑框架的抗震性能

获取原文
获取原文并翻译 | 示例
       

摘要

Steel braced frames consisting of strong beams, weak columns, and tension-only braces (BTFs) have been extensively used in low-rise steel buildings, since it is prefabricated rapidly and is cost-efficient. However, BTFs are vulnerable to soft story failure due to the negligible post-yielding stiffness of tension-only braces. A novel device of Energy-Dissipative Rocking Column (EDRC) is proposed to improve the seismic performance of BTFs. An EDRC consists of dual hinge supported steel column branches and replaceable steel strip dampers between them. Firstly, the effectiveness of EDRCs were verified through nonlinear time history analyses on benchmark multistory BTFs using a suite of far-field ground motion records. Secondly, systematic parametric studies are conducted to quantify the effect of key influencing factors such as stiffness ratio of EDRC to BTF and bending stiffness of column branches on the seismic performance improvement of BTF-EDRC systems. The results show that the maximum inter-story drift and inter-story drift concentration under earthquakes as well as the residual drift after earthquakes can be significantly mitigated by coupling with EDRC. It is found that the maximum inter story drift ratio can be reduced by 50% when the stiffness ratio of EDRC to BTF reached 1.0. The most effective stiffness ratio of EDRC to BTF for mitigating the inter-story drift concentration and residual drift ratio falls in a range of no more than 0.2 and 0.4, respectively.
机译:钢制支撑框架由强横梁,弱柱和仅受拉支撑(BTF)组成,已被广泛用于低层钢结构建筑中,因为它的预制速度快且具有成本效益。但是,由于仅张紧支架的屈服后刚度可忽略不计,因此BTF易受软故事破坏的影响。提出了一种新型的耗能摇摆柱(EDRC)装置,以提高BTF的抗震性能。 EDRC由双铰链支撑的钢柱分支和它们之间的可更换钢带减振器组成。首先,通过使用一组远场地面运动记录对基准多层BTF进行非线性时程分析,验证了EDRC的有效性。其次,进行了系统的参数研究,以量化诸如EDRC与BTF的刚度比和柱分支的弯曲刚度等关键影响因素对BTF-EDRC系统抗震性能改善的影响。结果表明,与EDRC耦合可以显着减轻地震作用下的最大层间漂移和层间漂移集中以及地震后的残余漂移。发现当EDRC与BTF的刚度比达到1.0时,最大层间漂移率可以降低50%。 EDRC与BTF缓解层间漂移浓度和残余漂移率的最有效刚度比分别在不超过0.2和0.4的范围内。

著录项

  • 来源
    《Engineering Structures》 |2019年第1期|109286.1-109286.10|共10页
  • 作者单位

    Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China;

    Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China;

    China Univ Min & Technol, Sch Mech & Civil Engn, Xuzhou 221116, Jiangsu, Peoples R China;

    Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Energy-Dissipative Rocking Column; Tension-only brace; Drift concentration; Soft story;

    机译:能量消耗摇摆柱;仅限张力;漂移浓度;柔软的故事;