An investigation was carried out to examine the influence of the fastener length on the elastic and ductile failure behaviour of typical steel-to-timber bracket connections in Cross Laminated Timber (CLT) manufactured from C16 spruce. The behaviour of single screw-type fasteners within CLT of length 25 mm, 50 mm and 75 mm are examined under tension and shear loading. Multiple screw-type fasteners have been utilised to examine monotonic and cyclic behaviour of steel bracket-fastened CLT connections under shear and tension loading. Characteristic values of the experimental results are compared to analytical models from current timber design codes and the literature. The length of fastener has been shown to influence the failure strength and ductility of the connection. The overstrength factors and strength degradation factors have been shown to be similar, regardless of fastener length, and conservative values are recommended.
机译:进行了一项调查,以研究紧固件长度对使用C16云杉制造的交叉层压木材(CLT)中典型的钢木支架连接的弹性和延性破坏行为的影响。在张力和剪切载荷下检查长度为25 mm,50 mm和75 mm的CLT内单螺钉型紧固件的性能。已使用多种螺钉型紧固件来检查在剪切力和拉力载荷下钢托架紧固的CLT连接的单调和循环行为。将实验结果的特征值与当前木材设计规范和文献中的分析模型进行比较。紧固件的长度已显示出会影响连接的破坏强度和延展性。事实证明,不管紧固件的长度如何,超强度因素和强度降低因素都是相似的,建议采用保守值。