首页> 外文期刊>Engineering Structures >Experimental investigation of bolted end-plate angle splice in encased composite columns
【24h】

Experimental investigation of bolted end-plate angle splice in encased composite columns

机译:封闭式复合柱螺栓端板角钢拼接的试验研究

获取原文
获取原文并翻译 | 示例
           

摘要

This study investigates a bolted end-plate splice of steel angles for encased composite columns. For the splice, two end plates, each of which is welded at the end of the spliced angle, are butted to each other, and connected in tension by one or three high-strength bolts. Since the centroids of the angle and bolt sections do not coincide, the deformation and prying force occurring at the connection need to be considered for design. Thus, the minimum thickness of end plate is proposed based on the yield line theory, and the tensile strength of the connection decreased by the prying force is estimated. The strength and failure mode of the connection are investigated through the direct tension tests of bare angle splice, and flexural tests of encased composite column with angle splice. The tests have shown that the connection is susceptible to slip and fracture in the threaded portion of bolt. In addition, the proposed minimum end-plate thickness and connection strength agree well with the test results.
机译:这项研究研究了封闭式复合材料柱的角钢螺栓端板接头。对于接头,将两个端板彼此对接,并通过一个或三个高强度螺栓将两个端板彼此对接,并在对接角的末端焊接该两个端板。由于角钢部分和螺栓部分的质心不一致,因此在设计时需要考虑在连接处产生的变形和撬力。因此,基于屈服线理论提出了端板的最小厚度,并估计了由于撬力而降低的连接件的抗拉强度。通过裸角接头的直接拉伸试验以及带角接头的封闭复合柱的弯曲试验,研究了连接的强度和破坏模式。测试表明,该连接在螺栓的螺纹部分易于打滑和断裂。此外,建议的最小端板厚度和连接强度与测试结果非常吻合。