This paper reports findings of an experimental study on floor trusses fabricated from cold-formed steel lipped channel sections. In design, the members of these trusses are generally considered as pin-ended and their capacities are assessed under pure compressive and tensile loads by making use of commonly accepted design specifications. Seventeen full-scale floor trusses were experimentally investigated through four point bending tests. Thickness of lipped channels, number of connection fasteners, and type of diagonal connection were considered as the prime variables. Test results indicate that there are marked differences between the design and measured values in terms of both the strength and stiffness. The service load stiffnesses of the trusses were found to be lower than the stiffnesses obtained using two dimensional truss models due to the neglect of connection flexibility in analysis models. Additional experiments on screw connections were conducted to find out their axial stiffness. The results from connection tests were used to develop analytical expressions which can be used to simulate connection flexibility. Similar to the stiffness, the strength of the trusses were found to be lower than the predicted strength using the pin-ended member under compression approach. In addition, the observed failure modes are markedly different than the code predictions. The sources of these differences were found to arise from the unfolding of lips at the diagonal to chord member connections and the global bending effects. The strength and failure mode of trusses can be more accurately predicted by considering local buckling of channel sections with unfolded lips.
机译:本文报道了由冷弯型钢唇形通道截面制成的楼板桁架的实验研究结果。在设计中,通常将这些桁架的构件视为带销的,并通过使用公认的设计规范在纯压缩和拉伸载荷下评估其能力。通过四点弯曲试验,对十七个全尺寸地板桁架进行了实验研究。主要的变量是唇形通道的厚度,连接紧固件的数量以及对角连接的类型。测试结果表明,就强度和刚度而言,设计值和测量值之间存在明显差异。由于忽略了分析模型中的连接灵活性,发现桁架的使用载荷刚度低于使用二维桁架模型获得的刚度。进行了螺纹连接的其他实验,以了解其轴向刚度。连接测试的结果用于开发可用于模拟连接灵活性的解析表达式。与刚度相似,在压缩方法下使用销钉端部构件时,发现桁架的强度低于预测的强度。此外,观察到的故障模式与代码预测明显不同。这些差异的根源是由于对角线到弦杆连接处的唇部展开以及整体弯曲效应而引起的。通过考虑唇形未展开的通道截面的局部屈曲,可以更准确地预测桁架的强度和破坏模式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号