Open-frame buildings are often used to provide a measure of weather protection over equipment or other sheltered storage on industrial sites. These shelters have a roof covering and minimal wall cladding, if any. ASCE 7 provides no guidance on the wind loads acting perpendicular to the frames that would control the design of the longitudinal braces. This paper summarizes wind tunnel tests that were performed on open-frame, low-rise buildings with a roof covering to determine the base shear and bracing loads parallel to the ridge. Two examples are provided to illustrate how the results of this study may be used to obtain the forces in longitudinal bracing.
机译:开放式建筑物通常用于为工业现场的设备或其他有遮盖的仓库提供某种程度的天气保护。这些避难所有一个屋顶覆盖物和最小的壁板(如果有)。 ASCE 7没有提供关于垂直于框架作用的风荷载的指导,而这会控制纵向支撑的设计。本文总结了在具有屋顶覆盖物的开放式低层建筑上进行的风洞测试,以确定平行于山脊的基础剪力和支撑载荷。提供了两个示例来说明如何将这项研究的结果用于获得纵向支撑中的力。