Fatigue cracking has been the cause of a number of high-mast lighting tower (HMLT) failures throughout the United States. In almost every case, forensic evaluations have shown cracking initiates and propagates due to wind-induced fatigue at mainly the base plate-to-tube wall connection detail or the hand-hole weld detail. Subsequent inspections of HMLT inventories have revealed a number of additional cases of fatigue cracking in various stages. Simply replacing the towers is not an economically feasible alternative because thousands of HMLTs are in use along major highways across the United States. As a result, strategies to retrofit existing HMLTs are needed. Results from laboratory testing performed on two HMLT retrofit configurations are presented. Both retrofits provided an increase in fatigue life compared with the as-built HMLTs. The retrofit strategies are employed without removing the pole from the foundation using simple bolting techniques and moderately skilled labor, providing cost savings for owners and increasing safety for the motoring public.
机译:疲劳开裂已成为导致整个美国许多大型桅杆照明塔(HMLT)故障的原因。几乎在每种情况下,法医评估都表明,裂纹是由风引起的疲劳引起的,并主要在底板到管壁的连接部位或手孔焊缝处蔓延。随后对HMLT库存的检查发现,在不同阶段还出现了许多其他疲劳裂纹案例。仅替换塔楼在经济上并不可行,因为在美国主要公路上使用了数千个HMLT。结果,需要改进现有HMLT的策略。给出了在两种HMLT改造配置上进行的实验室测试的结果。与HMLT相比,两次翻新都增加了疲劳寿命。采用改造策略时,无需使用简单的螺栓连接技术和中度熟练的劳动力就可以将杆从基础上移开,从而为业主节省了成本,并为驾车人士增加了安全性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号