The performance of ground source heat pumps (GSHPs) depends strongly on the heat transfer between the soil and borehole heat exchangers (BHEs). In the present work, a thermal performance experiment of a BHE under groundwater flow was conducted in Baoding, China. Based on the measurement of the natural ground temperature profile, a simplified theoretical model was presented to estimate the characteristics of groundwater flow. The results showed that the presence of groundwater had an obvious influence on the temperature profile in the aquifer. Due to the strong groundwater advection, the thermal performance of the BHE was enhanced. The enhanced effect depends to a great extent on the distribution and thickness percentage of the ground layer with the greatest groundwater flow. In the present case, the heat injection and heat extraction of the BHE were enhanced on average by 9.8% and 12.9%, respectively, compared with the case without groundwater flow, when the total thickness of coarse sand and gravel layer as a percentage of the borehole depth was 10.6%. This enhanced effect is favorable for reducing the possible imbalance between heat injection and extraction from and to the ground, which is helpful for the long-term operation of GSHP systems.
机译:地源热泵(GSHP)的性能在很大程度上取决于土壤和井壁热交换器(BHE)之间的热传递。在目前的工作中,在中国保定市进行了BHE在地下水流下的热性能实验。基于对自然地面温度分布的测量,提出了一个简化的理论模型来估算地下水流的特征。结果表明,地下水的存在对含水层的温度分布有明显的影响。由于强烈的地下水平流作用,BHE的热性能得以提高。增强效果在很大程度上取决于具有最大地下水流量的地层的分布和厚度百分比。在当前情况下,当粗砂和砾石层的总厚度占总厚度的百分比时,与没有地下水流的情况相比,BHE的热注入和热量提取分别分别平均增加了9.8%和12.9%。钻孔深度为10.6%。这种增强的效果有利于减少热量注入与从地面抽出之间的不平衡,这对于GSHP系统的长期运行很有帮助。

著录项

  • 来源
    《Energy and Buildings》 |2009年第12期|1368-1373|共6页
  • 作者单位

    School of Energy and Environment Engineering, Hebei University of Technology, Tianjin 300401, PR China;

    School of Energy and Environment Engineering, Hebei University of Technology, Tianjin 300401, PR China;

    School of Energy and Environment Engineering, Hebei University of Technology, Tianjin 300401, PR China;

    School of Energy and Environment Engineering, Hebei University of Technology, Tianjin 300401, PR China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ground source heat pump; borehole heat exchanger; groundwater flow; thermal performance;

    机译:地源热泵;钻孔换热器地下水流量热性能;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号