首页> 外文期刊>Energy and Buildings >Experimental study of a local ventilation strategy to protect semi-exposed relics in a site museum
【24h】

Experimental study of a local ventilation strategy to protect semi-exposed relics in a site museum

机译:在遗址博物馆中保护半暴露文物的局部通风策略的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

Indoor environmental controls are critical considerations when preserving artifacts in museums. Controlling the indoor environment of site museum buildings with large space layout typically consumes large amounts of energy. Most of the energy load needed to preserve relics is dissipated throughout the non-occupied space, because the environments that contain the relics occupy relatively little space compared to the entire exhibition hall. In this study, an energy efficient local ventilation system was proposed to independently control the environment of a funerary pit, which was preserved within a museum separate from the large exhibition hall. An experimental hall, which consists of a funerary pit and an experimental local ventilation system, was built to simulate a site museum building. Experiments were conducted to investigate the system's performance and to validate its ability to preserve historical terracotta figurines in their semi-exposed pits within the exhibition hall. The study evaluated the stability of the conservation environment and the system's energy usage by assessing the effects of the ventilation rate. The experimental results showed that the local ventilation system provides an energy-saving strategy supporting the environmental control of the funerary pit. The LV system significantly decreased temperature fluctuations in the funerary pit and temperature differences across semi-exposed relics. The system could be used to control the local preservation environment of the funerary pit separately from a large space exhibition hall. (C) 2017 Elsevier B.V. All rights reserved.
机译:在博物馆内保存文物时,室内环境控制是至关重要的考虑因素。控制具有大型空间布局的景点博物馆建筑物的室内环境通常会消耗大量能量。保存文物所需的大部分能量负荷在整个非占用空间中消散,因为与整个展厅相比,包含文物的环境占据的空间相对较小。在这项研究中,提出了一种高效节能的局部通风系统,以独立控制a葬场的环境,该fun葬场保存在与大型展览馆分开的博物馆中。建立了一个由hall仪馆和实验性局部通风系统组成的实验大厅,以模拟现场博物馆的建筑。进行了实验以调查该系统的性能,并验证其在展厅内半裸露的坑中保存历史兵马俑的能力。该研究通过评估通风速率的影响来评估保护环境的稳定性和系统的能源使用。实验结果表明,局部通风系统提供了一种节能策略,支持the葬场的环境控制。低压系统显着降低了半露天遗迹中丧葬坑的温度波动和温度差。该系统可用于与大型空间展示厅分开控制丧葬坑的本地保存环境。 (C)2017 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Energy and Buildings》 |2018年第1期|558-571|共14页
  • 作者单位

    Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China;

    Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China;

    Xi An Jiao Tong Univ, Shaanxi Energy Environm & Bldg Energy Conservat E, Xian 710049, Shaanxi, Peoples R China;

    Emperor Qinshihuangs Mausoleum Site Museum, Xian 710600, Shaanxi, Peoples R China;

    Shaanxi Prov Inst Conservat Cultural Heritage, Xian 710075, Shaanxi, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Local ventilation system; Relic preservation; Energy saving; Site museum; Local environmental control;

    机译:局部通风系统;文物保护;节能;场地博物馆;局部环境控制;
  • 入库时间 2022-08-18 00:08:33